  • Page 2 Fax: +49 6262 32 55 email: mail@brune.info Internet: www.brune.info Translation of the original operating manual Prok-22117-DE, 2, en_US This operating manual was created by: Kothes! Technische Kommunikation GmbH & Co. KG Internet: www.kothes.de © Brune Luftbefeuchtung Proklima GmbH 2012 Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 3 Information about this oper- ating manual This operating manual allows the safe and efficient use of the Evaporation Humidifier B500 Professional. This operating manual is an integral part of the humidifier and must be stored, readily accessible for the per- sonnel, in close proximity of the device.
  • Page 4 Copyright The content of this operating manual is copyrighted. Their use is allowed, in the context of the application of the device. Any further use is not permitted without written permission of Brune Luftbefeuchtung Proklima GmbH. Customer service Address Brune Luftbefeuchtung Proklima GmbH Schwarzacher Straße 13...
  • Page 5: Table Of Contents

    5.1 Indicators on the device......36 5.2 Switching on and off........37 5.3 Filling the water tank........37 5.4 Setting the desired air humidity....39 5.5 Regulating the fan........39 5.6 Changing the menu settings....... 40 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 6 10 Disposing of the humidifier......79 11 Technical data........... 80 11.1 Dimensions and weight......80 11.2 Connection values........80 11.3 Performance data........80 11.4 Operating conditions......... 81 11.5 Emissions..........81 11.6 Type plate..........81 12 Index..............82 Appendix............84 Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 7 Intentionally blank page 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 8: The Evaporation Humidifier B500 Professional

    The Evaporation Humidifier B500 Professional The Evaporation Humidifier B500 Professional 1.1 Complete Overview Fig. 1: Evaporation Humidifier B500 Filling opening Air inlet opening Air outlet opening Water tank Control panel Cover Accessories The following chapters provide only the description of the humidifier's standard version.
  • Page 9 Scope of supply Fig. 2: Scope of supply Item Quantity Name Fig. 1 Evaporation Humidifier B500 Professional, incl. power plug Wireless sensor system AA batteries for wireless sensor system Remote control AAA batteries for remote control Cleaning brush Operating manual...
  • Page 10: Remote Control

    The Evaporation Humidifier B500 Professional 1.2 Remote control Item Name Function [Humidity] Using the [Humidity] rocker switch rocker the target value for the air humidity switch can be set. By pressing several times or continuously the "+" or "-" area the desired humidity value can be increased or decreased.
  • Page 11: Control Panel

    The Evaporation Humidifier B500 Professional 1.4 Control panel The control panel provides information about the state of the device. It provides information about the current water level, the current air humidity value and any pos- sible device malfunctions. Fig. 5: Control panel...
  • Page 12: Functional Description

    The Evaporation Humidifier B500 Professional Item Name Function Display The following information is shown on the display: Actual/target value of air humidity Menu codes in programming mode Error codes during malfunctions [Malfunction indication] Lights up when a malfunction of the humidifier is pre- sent.
  • Page 13: Safety

    L CAUTION! Risk of getting pinched on cover plate! Carefully close cover plate. Tighten the screw. Tips and recommendations This symbol emphasizes useful tips and recommenda- tions as well as information for an efficient and fault-free operation. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 14: Intended Use

    Operating controls (e.g. buttons, switches), display elements (e.g. indicator lamps) 2.2 Intended use The Evaporation Humidifier B500 Professional is used exclusively to humidify the room air in private and pro- fessional environment. Heeding all the information in this operating manual is also part of the intended use.
  • Page 15: Symbols On The Device

    – Replace damaged signs or decals immediately. Over time, decals and signs can get dirty or defaced in any other way, so that risks can not be detected and the necessary operating instructions can not be followed. This may cause injury. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 16 The sign at the filling opening provides important instructions for cleaning and care of the humidifier. For detailed instructions on cleaning and care of the humidi- Ä Chapter 6 “Cleaning and servicing the fier heed humidifier” on page 43. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 17: Safety And Dangers

    – Never pull the device using the cable. Risk of imminent fatal injury from electric shock due to contact with live parts. Damaged insulation or damaged individual components can be dan- gerous to life. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 18 The liquid may cause burns when in contact with skin or severe poi- soning if swallowed and can cause blindness when contact with the eyes. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 19 Ä Chapter 6.2 “Cleaning schedule” described in on page 44. – Every 3-4 weeks, completely drain residual water from the water tank and refill water tank again. Bacteria and germs can be released when not cleaned adequately. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 20 L CAUTION – Lay the power cable in a manner that there is no risk of tripping. Risk of tripping exists if the power cable is not laid properly. This can lead to falls and injuries. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 21: Responsibilities Of The Owner

    The owner must ensure that all persons who handle the device have read and understood this operating manual. The owner must provide the personnel with the necessary protective equipment and instruct that wearing the required protective equipment is manda- tory. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 22: Personnel Requirements

    He must furthermore provide proof of his professional qualification, attesting to the ability to carry out work on sanitary equipment. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 23: Environmental Protection

    Incorrect handling of environmentally hazardous substances, in particular incorrect disposal, can cause considerable damage to the environment. The following environmentally hazardous sub- stances are used: 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 24 Safety Batteries Batteries contain toxic heavy metals. They are subject to treatment of special refuse and must be deposited at municipal collection points or be disposed of by a spe- cialist company. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 25: Transport And Storage

    Keep dry Protect packages from wet conditions and keep them dry. The arrow peaks of the symbol indicate the upper part of the package. They should always point upwards to prevent damage to the content. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 26: Storage Of Packages

    Complain about any defect, as soon as detected. Damage claims can only be filed within the applicable period for complaints. 3.5 Storage when not in use When the humidifier is not in operation for a longer period of time, proceed as follows: Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 27: Transporting The Humidifier

    Observe the following when the humidifier's place of installation is changed: Whenever possible, move the humidifier along its longitudinal axis (Fig. 7/arrow). For this seize the humidifier at the green marked area (Fig. 7). Fig. 7: Moving the humidifier 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 28 Transport and storage If the humidifier is moved transverse to its longitu- dinal axis, additionally seize it at the bottom side (Fig. 8). Fig. 8: Moving the humidifier transverse to its longitudinal axis Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 29: Commissioning

    However, the direct tem- perature influence should not exceed 70 °C (158 °F). On water sensitive flooring additional safety measures must be provided. 4.3 Commissioning the humidifier for the first time To commission the humidifier proceed as follows: 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 30 Fig. 10: Wrong fit of filter Remote control Replace cover of device. Commissioning the wireless Personnel: Operator sensor system Carefully lift and remove the cover of the wireless sensor system using a small screwdriver. Fig. 11: Open cover Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 31 Fill up the water tank of the humidifier using tab water. For this, proceed as indicated under Ä Chapter 5.3 “Filling the water tank” on page 37. Switch on the humidifier using the [ON/OFF] button on the remote control. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 32: Coding The Wireless Sensor System

    Several devices are operated via one sensor. For this, all devices should have the same coding. Each device is controlled via a separate sensor. For this, all devices have to be coded differently. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 33 Ensure that you do not touch the electronics and do not damage any components. Carefully lift and remove the cover plate of the wireless sensor system using a small screwdriver (Fig. 16). Fig. 16: Open cover 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 34 (Fig. 18). Fig. 18: Remove cover Use a screwdriver to loosen and unscrew the four screws at the top of the control panel (Fig. 19/1) by turning counter-clockwise. Fig. 19: Loosening the control panel Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 35 Close cover of the device again. Check the system functioning. For this, carefully breathe into the housing of the wireless sensor system. ð The actual value indicated on the control panel changes. The wireless sensor system is ready for operation. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 36: Operating The Humidifier

    The speed of the fan is controllable in four levels. The device has additionally an automatic function. The speed level of the fan is indicated via the [Indication "Fan speed level"] at the control panel. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 37: Switching On And Off

    Improper filling Risk of electrical shock from improper filling! L DANGER – Carefully pour in water. – Always use a funnel for filling. Improper filling can lead to death or serious injury from electrical shock. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 38 Using a watering can carefully fill the water tank (up to 50 liters / 13.2 gallons). Close the fill flap again. Fig. 22: Open fill flap ð The [Indication "Water level"] shows the current fill level (max. 5 bars). Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 39: Setting The Desired Air Humidity

    Now increase or decrease the fan speed using the "+" and "-" area of the [Fan] rocker switch. ð The current fan speed level is shown in the [indication "Fan speed level"]. To activate the fan automatic, proceed as follows: 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 40: Changing The Menu Settings

    ("+" area) or down ("-" area). Once the change has been performed, wait 10 seconds. ð The display read-out jumps back to the default state (display of the actual humidity value). The changes have been saved. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 41 01 = ON Relay active, if UV lamp 00 = OFF defective. 01 = ON Relay active, if fill 00 = OFF amount of water tank ≥ 01 = ON 50 liters (13.2 gallons). 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 42 90%. The actual 01 = ON switch-on mechanism. value constantly shows 00%. The fan setting is freely selectable. Adjustment/control 01 ... 10 Depending on room size. interval of fan during min. automatic operation Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 43: Cleaning And Servicing The Humidifier

    Ä Chapter 6.2 “Cleaning schedule” on page 44. – Every 3–4 weeks, completely drain residual water from the water tank and refill water tank again. Bacteria and germs can be released when not cleaned adequately. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 44: Cleaning Schedule

    The protective goggles are used to protect the eyes from splashes. 6.2 Cleaning schedule The indicated time intervals apply on normal water quality and normal dust occurrence in the air and can therefore deviate up or down. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 45: Cleaning Tasks

    “Cleaning the UV degermination system and lime transforming cartridge” on page 72). 6.3 Cleaning tasks 6.3.1 Monthly cleaning Personnel: Operator L WARNING! Risk of electrical shock if the power plug is not disconnected! Switch off humidifier and disconnect power plug. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 46 Fig. 24: Clean drainage holes Lift center piece from the water tank and place on the lateral surface (Fig. 25). Empty residual water from water tank. Clean water tank with a sponge. Fig. 25: Remove center piece Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 47: Replacing The Evaporation Filter

    Switch off humidifier and disconnect power plug. Lift the cover of the humidifier upwards and place to the side (Fig. 27). Fig. 27: Remove cover Press filter bracket together and unhinge (Fig. 28). Fig. 28: Remove filter bracket 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 48 Fig. 30: Wrong fit of filter Fasten filter on both sides to the attachment hooks (Fig. 31/1). Check that the filter sits tight in the rail of the water distribution and that no fibers stick out. Fig. 31: Fasten filter Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 49: Cleaning The Water Tank

    L WARNING! Risk of electrical shock if the power plug is not disconnected! Switch off humidifier and disconnect power plug. Lift the cover of the humidifier upwards and place to the side (Fig. 33). Fig. 33: Remove cover 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 50: Decalcifying The Device

    Lime remover L WARNING! Risk of electrical shock if the power plug is not disconnected! Switch off humidifier and disconnect power plug. To prevent damage to the surface, place the humidifier on a moisture-resistant flooring. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 51 Switch off humidifier and disconnect power plug. Lift the cover of the humidifier upwards and place to the side (Fig. 36). Remove cleaning brush from side box. Fig. 36: Remove cover 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 52 (order no.: 1529). Reattach pump hoses. Ensure tight and proper fit of pump hoses. Oth- erwise water could leak out. Fig. 39: Clean pump hoses Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 53 Place center piece back into the water tank and replace cover. Fig. 41: Clean copper elec- trodes Vacuum the fan (Fig. 42/1) surface using a suitable vacuum nozzle. Fig. 42: Vacuum fan 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 54: Detect And Remedy Malfunctions

    Improper troubleshooting can cause serious or fatal injuries. 7.2 Malfunction indication The Evaporation Humidifier B500 Professional has an independent monitoring system that provides the possi- bility to quickly and reliably detect errors and respond accordingly. If a malfunction is present, it is displayed on the mal- function indication on the control panel.
  • Page 55 Water tank overfilled Check functionality of solenoid valve. Operator (only possible on auto- Check water level electrodes for contam- matic water supply ination and clean if required (optional accessory)) Ä Chapter 6.3.1 “Monthly cleaning” on page 45). 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 56: Error Table

    37). tank empty"] illumi- Copper elec- Clean copper electrodes Operator nates red. Ä Chapter 6.3.4 “Decalcifying the trodes of the water level indi- device” on page 50). cation are dirty. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 57 Pump hoses Connect pump hoses correctly and if Operator Ä Chapter 6.3.4 not properly required clean ( connected or “Decalcifying the device” on page 50). dirty. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 58 Ä “Error code display” on page 55. on the control panel humidifier has display. In addition detected a an alarm sounds. problem. Except for the [ON/OFF] button as Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 59: Remedying Errors

    L WARNING! Risk of electrical shock if the power plug is not disconnected! Switch off humidifier and disconnect power plug. Lift the cover of the humidifier upwards and place to the side (Fig. 43). Fig. 43: Remove cover 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 60 (Fig. 45/1). Fig. 45: Water pump To collect any possible residual water, place a suit- able vessel under the pump hoses (Fig. 46/1). Take off pump hoses. Fig. 46: Take off pump hoses Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 61 Insert the water pump in the opening and turn in the arrow direction until it latches in and sits tight (Fig. 49/1). Ensure that the pump cable is not crushed when inserting the pump. Fig. 49: Install pump 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 62: Replacing The Fan

    ð The fan is located in the center piece next to the control panel. Fig. 51: Remove cover Loosen and pull out the fan plug by pressing the plug clamps (Fig. 52/1). Fig. 52: Removing the fan plug Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 63 Insert new fan Insert new fan. Run the screw threads on the vibration dampers through the holes in the center plate. Retighten fan at the bottom of the center piece (Fig. 55/1). Fig. 55: Tighten fan 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 64 Detect and remedy malfunctions Connect fan plug again (Fig. 56/1). Place center piece back into the water tank and replace cover. Fig. 56: Connect fan Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 65: Accessories

    Accessories Accessories Risk of injury due to using wrong accessories! L WARNING – Only use original accessories from Brune Luft- befeuchtung Proklima GmbH or accessories authorized by Brune Luftbefeuchtung Proklima GmbH. – Always contact our customer service for any questions.
  • Page 66 Risk of property damage due to excessive water NOTICE pressure! – The maximum water pressure may not exceed 1 MPa (145 psi). The humidifier can be damaged if the water pres- sure of the local water supply system is too high. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 67: Automatic Flushing Device

    [Flush] button. In addition to the manual start, the flushing device can be programmed so that the water is automatically exchanged in intervals of 1–7 days. For this proceed as follows: 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 68 To fill the water column, fill hose prior to con- nection with water. To prevent a vacuum formation, equip the line with a bleeder (if required). For dimensions and connection sizes see drawing Fig. 57. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 69: Activated Charcoal Cleaning Filter

    (Fig. 59/1). To replace the activated charcoal cleaning filter, proceed as follows . Fig. 59: Clamping bracket for activated charcoal cleaning filter 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 70: Replacing The Activated Charcoal Cleaning Filter

    Fig. 61: Remove plastic sleeves the same distance from each other as the holes of the filter. If required, adjust the width of the filter bracket by carefully bending. Reattach plastic sleeves. Replace cover of humidifier. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 71: Air Hood With Flexible Air Hose

    In addition, the device can be equipped with a lime transforming cartridge that changes the molecular struc- ture of lime so that it can no longer accumulate on the surfaces in the device. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 72: Cleaning The Uv Degermination System And Lime Transforming Cartridge

    L WARNING! Risk of electrical shock if the power plug is not disconnected! Switch off humidifier and disconnect power plug. Lift the cover of the humidifier upwards and place to the side (Fig. 63). Fig. 63: Remove cover Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 73 Fig. 65: UV degermination system Take the pump hoses off the stainless steel pipe and clean using the cleaning brush. In case of severe contamination or wear, replace pump hoses. Fig. 66: Clean pump hoses 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 74 (Fig. 68/3) and tilt to the side. Take off pump hoses (Fig. 68/ 2) and remove lime transforming cartridge. Fig. 68: Lime transforming car- tridge Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 75: Replacing The Uv Lamp

    To replace this, proceed as follows: Personnel: Operator L WARNING! Risk of electrical shock if the power plug is not disconnected! Switch off humidifier and disconnect power plug. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 76 Remove the control panel and place on the oper- ating side (Fig. 72). ð The UV lamp is located in a metal housing below the control panel (Fig. 73/1). Fig. 72: Remove the control panel Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 77 Attach connection cable to the new UV lamp. Carefully insert the UV lamp into the quartz glass body. Place the control panel again and fasten using the Fig. 74: Remove connection four screws. cable Replace cover of device. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 78: Spare Parts

    Spare parts Risk of injury due to using wrong spare parts! L WARNING – Only use original spare parts from Brune Luftbe- feuchtung Proklima GmbH or spare parts author- ized by Brune Luftbefeuchtung Proklima GmbH. – Always contact our customer service for any questions.
  • Page 79: Disposing Of The Humidifier

    – In case of doubt, information about correct dis- posal can be obtained from the local authorities or from special waste management companies. Wrong disposal can pose risks to the environment. 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 80: Technical Data

    11.3 Performance data Data Value Unit Air output 900 / 3962 m³/h / gal/min Evaporation performance 2.6 / 16.5 l/h / US Evaporation filter surface 3.5 / 37.7 m² / sq Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 81: Operating Conditions

    11.6 Type plate The type plate is located under the cover above the power connection and contains the following informa- tion: Manufacturer Type Series Serial number Fig. 75: Type plate Electrical power and connection values 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 82: Index

    Malfunctions........... 54 Dangers..........17 Detecting..........54 Decalcifying..........50 Overview..........56 Defects........... 54 Remedying......... 59 Dimensions..........80 Menu overview........41 Disposal..........79 Noise emission........81 Electrical current........17 Emissions..........81 Operating conditions....... 81 Environment........... 81 Operation..........36 Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 83 Replacing the UV lamp......75 Water tank Residual risks......... 17 Cleaning..........49 Filling..........37 Safety signs..........15 Weight............ 80 Scope of supply........9 Wireless sensor system......10 Setting Coding..........32 Air humidity........39 Fan............. 39 Menu..........40 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 84: Appendix

    Appendix Appendix Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 85 Appendix Table of content for the appendices Parts list............. 86 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 86: Parts List

    – For any problem, where the solution is not described in this operating manual, contact the local specialized retailer. The illustrations and parts list in the following are only intended for specialized retailers. Unauthor- ized disassembling of the humidifier may cause serious injury. Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 87 Parts list 2013-11-04 Evaporation Humidifier B500 Professional...
  • Page 88 Crown gear M 4 us1347 Base circuit board 510 for B 500 1566 U washer M 4 professional incl. additional cir- cuit board for speed-blower/fan 1348/3 Measurement / transmission 1567 U disc V2 M 5 x 15 module Evaporation Humidifier B500 Professional 2013-11-04...
  • Page 89 Quartz dip tube us1403 Adhesive part extension right us1724 Fluorescent lamp ballast for UV- side Technology 1406/1 Remote control WITHOUT bat- 1727 V4A tube teries us1411 Filler rods without rib (6) 2520 Screw/bolt M4x12 strain relief 2013-11-04 Evaporation Humidifier B500 Professional...