Zone Options - Zones 49 To 64 - NAPCO FREEDOM F-64 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for FREEDOM F-64:
Table of Contents

Advertisement

WI1502A 9/06
ZONE OPTI ONS - ZONE S 49 T O 6 4 (A DDRESS 12 8 5-1 4 00 )
ZONE FEATURES
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
Alarm Output
Pulsed Alarm Output
PGM1 Output
PGM2 Output
Entry/Exit 1
Entry/Exit 2
Exit/Entry Follower
Auto Reset
Swinger Shutdown
Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
Alarm Telco 1
Alarm Restore 1
Trouble Telco 1
Trouble Restore 1
Alarm Telco 3
Alarm Restore 3
Trouble Telco 3
Trouble Restore 3
No EOL Resistor
Trouble on Open
Trouble on Short
Zone Area 1
Zone Area 2
Zone Area 3
Zone Area 4
Interior (Stay) Bypass
Keypad Sounder on Alarm
(C)
Fire
(C)
Fire Alarm Verification
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Sensor Watch
RESERVED
Chime 2
RESERVED
Perimeter Group Bypass
When the Easy Menu Driven Program Mode is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
NOTES: (A) 50ms Loop Response only available for zones 1-8. If Zone Doubling is enabled, Zones 9-16 will follow the loop response programming for Zones 1-8. For all
other Zones, loop response is determined by jumpers on the GEM-EZM8 and/or the configuration on the F-64PROG.
(B) 2-wire Smoke Detectors only available for zones 7 & 8, and Fire must also be selected.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Program Mode.
Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown and Zone Area 1 are enabled for the total number of zones entered in "# OF ZONES IN AREA1 ENTER #
ZONES".
Alarm Telco 1 is enabled for the zone number(s) entered in "REPORT ALL ZONES TO CENTRAL ZONES? Y/N".
Entry/Exit 1 and Chime are enabled for the zone number(s) entered in "ENTRY/EXIT ZONES ENTER ZONE #".
Exit/Entry Follower and Interior Bypass are enabled for the zone number(s) entered in "INTERIOR ZONES ENTER ZONE #".
Pulse Alarm Output is enabled for the zone number(s) entered in "FIRE ZONES ENTER ZONE #" or "2-WIRE FIRE ZNS ENTER ZONE #".
Fire is enabled for the zone number(s) entered in "FIRE ZONES ENTER ZONE #".
2-Wire Smoke Detector is enabled for the zone number(s) entered in "2-WIRE FIRE ZNS ENTER ZONE #".
L
NAPCO Security Systems
ZONES 49 → 56
ADDR Z49 Z50 Z51 Z52 Z53 Z54 Z55 Z56 ADDR Z57 Z58 Z59 Z60 Z61 Z62 Z63 Z64
1
2
3
4
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1327
1328
1330
1331
1332
1333
1334
1335
1336
1337
1338
5
6
7
8
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1391
1392
1394
1395
1396
1397
1398
1399
1400
1401
1402
Freedom F-64 Programming Instructions
Page 33
ZONES 57 → 64
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-64prog

Table of Contents