Options - NAPCO FREEDOM F-64 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for FREEDOM F-64:
Table of Contents

Advertisement

WI1502A 9/06
To program, follow the 5 steps below.
STEP 1
RELAY # OPTIONS:
The F-64 supports 16 external relays from Relay Module RM3008. Multi-
ple events may be "mapped" to each relay, up to a maximum of 32
events.
Select the relay number from Table 1 (next page); enter in corresponding address location.
STEP 2
AREA OPTIONS:
Each relay event can be assigned to Area 1, 2, 3 and / or 4.
Select the area from Table 2 (on next page); enter in corresponding address location.
STEP 3
TIMEOUTS:
Each relay event can be assigned a timeout depending on Alarm Type option.
If Alarm Type is selected for timeout in minutes or seconds, enter the 3-digit timeout duration in correspond-
ing address location. To choose seconds or minutes, see step 5A below. 254 is maximum entry.
STEP 4
EVENT ID CODES:
Each relay event can be assigned any of the available event IDs from Table 4.
Select 2-digit Event ID from Table 4 (on next page); enter in corresponding address locations (left and right digit).
STEP 5
RELAY EVENT CONDITION OPTIONS:
select a timeout type for each. Enter 5A in left area, enter 5B in right area.
5A. Select Alarm Type and Timeout Type from Table 5A (on next page); enter in corresponding left address location.
5B. Select Activation Conditions from Table 5B (on next page); enter in corresponding right address location.
L
NAPCO Security Systems
RELAY #
See
Step 1 below
Step 2 below
Each relay event can be assigned an alarm type; and an activation condition; also,
RELAY EVENT OPTIONS
AREA
TIMEOUT
See
See
Step 3 below
Freedom F-64 Programming Instructions
Page 35
EVENT ID
COND.
See
See
Step 4 below
Step 5 below
Continued