Displays and Messages

Operation Messages

The LCD continuously scrolls through all relevant operating
data. Each message (MSG) is displayed for 5 seconds,
after all messages have been displayed the LCD repeats
from the beginning.
MSG #1 "E-Today" (total energy produced on this day) is
displayed together with the current operating mode:
MSG #2 Nominal grid voltage configuration and actual
line-to-neutral voltage measurements:
MSG #3 Actual AC power output and DC input:
MSG #4 Accumulated yield of the device since installation
and the total operating hours:
7-12
Note: The screens may also be scrolled through manually by
repeatedly knocking on the lid of the inverter. Each knock
advances the screen to the next message.
SMA America
E-today
3.86kWh
Mode
Energy produced today
and current operating mode
Gridtype - 208V
L1 120V L2 120V
Gridtype and phase-to-neutral
voltages
Pac
3200W
Vpv
380V
AC power
and DC voltage
E-total 724.4kWh
h-total
512h
Total energy yield
and total operating hours