8. Using the solder-less ring terminals, strip and terminate the individual wires.
9. Expose only sufficient copper (using a solder-less terminal crimping tool) to ensure a good electrical
connection. No exposed copper strands should be visible outside the terminal insulator.
10. Install the power cable ring terminals using the 2 screws and nut removed in steps 3 and 4.
• Black wire to terminal L (line)
• White wire to terminal N (neutral)
• Green wire to terminal G (ground)