Installing the Test Point Adaptor
Appliance
gas inlet pipe
Nipple
Gasket
Conical adaptor
Test point adaptor
Test point
Fig. 36
Important !
Use two wrenches to tighten the connection.
Note: take care not to overtighten the
conical adaptor, as doing so may crack the
test point adaptor.
Interpose the
supplied gasket.
Important !
Use two wrenches to tighten
the connection.
28
G 1/2 cylindrical
(ISO 228-1) male
G 1/2 cylindrical
(ISO 228-1) female
R 1/2 conical
(ISO 7-1) male
Rc 1/2 conical
(ISO 7-1) female
Rc 1/2 conical
(ISO 7-1) female
LOCK
Arrow
Fig. 37
LOCK
Fig. 38
Using a suitable leak detection
fluid solution (e.g. Rocol) check
each gas connection one at a time
by brushing the solution over the
connection.
The presence of bubbles will
indicate a leak.
If there is a leak, tighten the fitting
and then recheck for leaks.
IMPORTANT! Do not use a naked
flame to test for leaks.
OK
Fig. 39