Viessmann Vitodens 100 WB1 Technical Data Manual page 4

Gas-fired condensing boiler 8.8 to 25.6 kw
Table of Contents

Advertisement

Vitodens 100
Technical data
Gas boiler, type C
,
3
category II
2ELL 3P
*1
Rated output range
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
Rated thermal load
Product ID number
Gas supply pressure
Natural gas
LPG
*2
Max. gas supply pressure
Natural gas
LPG
Electrical power consumption, max.
(including circulation pump)
Weight
Capacity, heat exchanger
Heating water flow rate
with 200 mbar residual head
Max. flow rate
(limit value for use of hydraulic
decoupling)
Rated recirculated water volume
at ∆T = 20 K
Max. operating pressure
Connections
Boiler flow and return
Safety valve
Dimensions
Length
Width
Height
Height with DHW cylinder under boiler
Gas connection
*3
Instantaneous water heater
Capacity, domestic hot water
Capacity,
heating water
Connections, hot and cold water
Max. operating pressure
(secondary circuit)
Outlet temperature, adjustable
Recovery capability
with a temperature rise of the
domestic hot water from 10 to 45 °C
Domestic hot water drawing rate
Connection values
based on the max. load
with gas
with net c.v.
natural gas E
29.45 kWh/m
34.01 MJ/m
natural gas LL
28.13 kWh/m
29.25 MJ/m
LPG
12.79 kWh/m
46.04 MJ/m
*1
Values according to EN 677.
*2
If the gas supply pressure is higher than the maximum permissible value, a separate gas governor must be installed upstream of
the system.
*3
Minimum pressure for cold water connection 1 bar.
*4
Values for sizing the flue system to DIN 4705.
Flue gas temperatures are gross values measured at 20 °C combustion air temperature.
The data for the partial load refers to an output of 30 % of the rated output. Where the partial load differs (depending on the operat
ing mode of the burner), the flue gas mass flow rate must be calculated accordingly.
The flue gas temperature at a return temperature of 30 °C is the criterion for sizing the flue system.
The flue gas temperature at a return temperature of 60 °C is used for determining the application range of flue pipes with maximum
permissible operating temperatures.
4
kW
kW
kW
mbar
mbar
mbar
mbar
W
kg
ltr
ltr/h
ltr/h
ltr/h
bar
Ø" (male thread)
Ø" (fem. thread)
mm
mm
mm
mm
Ø" (male thread)
ltr
ltr
Ø" (male thread)
bar
°C
kW
ltr/h
ltr/min
3
3
m
/h
3
3
3
m
/h
3
3
kg/h
3
Gas central heating boiler
8.8 25.6
8 24
8.4 25
CE 0085 AU 0029
20
50
25.0
57.5
165
60
3.5
1 060
1 400
1 032
3
c
c
406
500
900
1 975
b
2.65
3.08
1.94
Gas combination boiler
8.8 25.6
8 24
8.4 25
20
50
25.0
57.5
165
63
4.3
1 060
1 400
1 032
3
c
c
406
500
900
1 975
b
1.0
0.7
b
10
38 57
24
590
3 8
2.65
3.08
1.94