Control unit for operation at constant temperature
Control unit for operation at constant temperature
Built into the Vitodens
H Electronic boiler control unit for oper
ation of the Vitodens with constant
boiler water temperature
Constructional design and functions
Construction
The control unit contains:
Heating system switch, display panel with
digital display, minimum temperature
regulator, limit thermostat (DIN Reg. No.
DIN TW 110898S, in the burner control
unit LGM 29.XX), electronics, selector
switch for operating mode, selector
knobs for boiler water temperature and
domestic hot water temperature, burner
fault lamp, emissions test switch, comfort
switch (only on gas combination boiler)
and integrated diagnosis system.
Technical data
Rated voltage:
230 V~
Rated frequency:
50 Hz
Rated current:
4 A
Protection class:
I
Degree of
protection:
IP X4 D to EN 60529
Method of
operation:
Type 1 B to EN 60730 1
Ambient temperature
H during operation: 0 to +40 °C
For use in living ac
commodation and
boiler rooms (normal
ambient conditions)
H during storage
H
and transport:
20 to +65 °C
Setting of electronic
limit thermostat
(central heating):
82 °C (resetting is not
possible)
Setting of electronic
limit thermostat
(DHW heating):
42 to 84 °C
Setting of high limit
safety cut-out:
100 °C (resetting is not
possible)
Setting range of
domestic hot water
temperature:
32 to 57 °C
12
H A clock thermostat, type A, F or M, is
required for room temperature depen
dent operation
Summer economy circuit
Heating program "w"
The burner is only switched on when the
cylinder has to be heated (switched by
the hot water cylinder control).
Boiler temperature sensor
The boiler temperature sensor is already
connected in the control unit and built
into the boiler.
Ambient temperature
H during operation: 20 to +130 °C
H during storage
and transport:
20 to +170 °C
Please note:
If hydraulic decoupling (i.e. a low loss
header) is used, a temperature sensor
must be connected for the common flow
downstream from the low loss header
(see Vitodens Technical Guide).
Frost protection function
The frost protection function is active in
all heating programs.
The burner is switched on at a boiler
water temperature of 5 °C and off again at
a boiler water temperature of 55 °C.
The circulation pump is switched on at
the same time as the burner and is
switched off again after a time delay.
For frost protection of the system, the cir
culation pump can be switched on addi
tionally to the burner for approx. 10 min
utes at certain intervals (up to 24 times
per day).
H Integrated diagnosis system
H Integrated hot water cylinder control
Cylinder temperature sensor
Included in standard delivery with
H connection kit for wall-mounted DHW
cylinders (80 litres) (to be ordered at
same time)
H connection kit for DHW cylinders (120
or 150 litres) positioned under boiler (to
be ordered at same time)
H connection kit for DHW cylinders (160,
200 or 300 litres) positioned remote to
boiler or other DHW cylinders (to be or
dered at same time)
Cable length approx. 3.75 metres, with
plug ready for connection
Degree of
protection:
IP 32
Ambient temperature
H during operation: 20 to +90 °C
H during storage
and transport:
20 to +70 °C