Control unit for weather-compensated operation
Built into the Vitodens
H Weather-compensated, digital boiler
control unit for modulating operation of
the Vitodens
H With standard programming unit
Constructional design and functions
Modular construction
The control unit comprises a basic unit,
electronic modules and a programming
unit.
The control unit contains:
Heating system switch, emissions test
switch, comfort switch (only on gas com
bination boiler), electronic maximum
temperature limiter, limit thermostat (DIN
Reg. No. DIN TW 110898S, in the burner
control unit LGM 29.XX), microcomputer,
facilities for setting switching times, tem
peratures in normal and reduced oper
ation, domestic hot water temperature,
adjustment of the heating curves, tem
perature scans, built-in diagnosis system
and fuses.
Boiler-specific functions
The control unit adjusts the boiler water
temperature (=flow temperature of a direct-
connected heating circuit and/or a heating
circuit with mixer in conjunction with the
extension kit for a heating circuit with
mixer) automatically and continuously to
the particular outdoor temperature. It has a
hot water cylinder control with priority con
trol of domestic hot water heating (heating
circuit pump off).
To comply with current energy-saving re
gulations, thermostatic valves should be
used for controlling the temperature in the
individual rooms.
Control unit for weather-compensated operation
H Digital programmer with day and week
feature with four programmable activa
tion periods per day for reduced oper
ation, release of domestic hot water
heating or release of DHW circulation
pump
Technical data
Rated voltage:
230 V~
Rated frequency:
50 Hz
Rated current:
4 A
Protection class:
I
Degree of
protection:
IP X4 D to EN 60529
Method of
operation:
Type 1 B to EN 60730 1
Ambient temperature
H during operation: 0 to +40 °C
For use in living ac
commodation and
boiler rooms (normal
ambient conditions)
H during storage
and transport:
20 to +65 °C
Setting of electronic
limit thermostat
(central heating):
82 °C (resetting is not
possible)
Setting of electronic
limit thermostat
(DHW heating):
42 to 84 °C
Setting of high
limit safety
cut-out:
100 °C (resetting is not
possible)
Setting range of
domestic hot water
temperature:
32 to 60 °C
Setting range of
heating curves
H Heating curve
slope:
0.2 to 2.6
H Heating curve
shift:
12 to +33 K
Standard programming unit
H Temperatures and error messages
shown in display
H Codings via programming unit display.
H Frost protection of the heating system
H Integrated diagnosis system
H Integrated hot water cylinder control
Timer of the programming unit
Digital programmer with day and week
feature, year calendar and automatic reset
ting to summer/winter time.
The time, day and standard switching
times are preset in the factory (individually
programmable), up to four activation
periods selectable per day.
Smallest switching
interval:
10 minutes
Power reserve:
15 years
Setting the heating programs
*1
Frost protection
of the heating system
features in all heating programs.
The following heating programs can be
selected with the program selector
switch:
H Continuous standby
H Domestic hot water heating only
H Normal operation/reduced operation or
normal operation/standby
H Continuous normal operation
H Continuous reduced operation.
*1
See "Frost protection function".
Frost protection function
The frost protection function is active in
all heating programs.
The frost protection function is
H switched on when the outdoor tempera
ture falls below approx. +1 °C.
In the frost protection function, the
heating circuit pump is switched on and
the boiler water is kept at a minimum
temperature of approx. 20 °C.
H switched off when the outdoor tem
perature rises above approx. +3 °C.
Summer economy circuit
Heating program "w"
The burner is only switched on when the
cylinder has to be heated (switched by
the hot water cylinder control).