Viessmann Vitodens 100 WB1 Technical Data Manual page 19

Gas-fired condensing boiler 8.8 to 25.6 kw
Table of Contents

Advertisement

WS remote control unit,
Part No. 7450 027
The remote control unit is used for set
ting the desired temperatures for normal
operation (day temperature) and reduced
operation (night setback temperature) of
one heating circuit from anywhere in the
building.
Only one remote control unit can be con
nected. If a heating circuit with mixer is
installed, the remote control unit is effec
tive for the heating circuit with mixer.
Electrical connection:
H 3-core cable (without "green/yellow"
wire), max. cable length 30 metres with a
conductor cross-section of 1.5 mm
copper.
H Cable must not be laid together with
230/400 V lines.
Protection class:
III
Degree of protection:
IP 30
Ambient temperature
H during operation:
20 to +40 °C
H during storage
and transport:
20 to +65 °C
Setting range of desired
room temperature
H Locking switch "s":
14 to 26 °C
H Locking switch "m":
17 to 23 °C
Desired room
temperature in
selector switch
setting "9":
13 to 25 °C
Control unit for weather-compensated operation
RS remote control unit,
Part No. 7450 028
The remote control unit is used for set
ting the desired temperatures for normal
operation (day temperature) and reduced
operation (night setback temperature) of
one heating circuit from the main living
room (master room).
The built-in room temperature sensor
measures the room temperature and acti
vates any necessary correction of the
flow temperature.
Only one remote control unit can be con
nected. If a heating circuit with mixer is
installed, the remote control unit is effec
2
tive for the heating circuit with mixer.
The remote control unit is mounted on
the inside wall of the main living room
opposite the radiators, but not in shelves,
alcoves or immediately next to doors or
sources of heat (e.g. in direct sunlight,
next to a fireplace, TV set etc.).
Electrical connection:
H 3-core cable (without "green/yellow"
wire), max. cable length 30 metres with a
conductor cross-section of 1.5 mm
copper.
H Cable must not be laid together with
230/400 V lines.
Protection class:
Degree of protection:
Ambient temperature
H during operation:
H during storage
and transport:
Setting range of desired
room temperature
H Locking switch "s":
H Locking switch "m":
Desired room
temperature in
selector switch
setting "9":
Room temperature sensor,
Part No. 7408 012
Separate room temperature sensor to
supplement the RS remote control unit in
applications where the RS remote control
unit cannot be located in the main living
room or at an optimum position for tem
perature measurement/ setting purposes.
The room temperature sensor is mounted
on the inside wall of the main living room
opposite the radiators, but not in shelves,
alcoves or immediately next to doors or
sources of heat (e.g. in direct sunlight,
next to a fireplace, TV set etc.).
The room temperature sensor is con
nected to the RS remote control unit.
Electrical connection:
H 2-core cable with a conductor cross-sec
tion of 1.5 mm
H The cable length between the control
unit, remote control unit and room
temperature sensor must not exceed
30 metres.
H Cable must not be laid together with
230/400 V lines.
2
Protection class:
Degree of protection:
Ambient temperature
H during operation:
III
H during storage
IP 30
and transport:
20 to +40 °C
20 to +65 °C
Adaptor (connection extension),
Part No. 7404 582
14 to 26 °C
A maximum of 2 adaptors can be con
17 to 23 °C
nected.
One of the following functions can be im
plemented with an adaptor:
H Connection of an external safety sole
13 to 25 °C
noid valve (LPG).
H Interlocking of external exhaust air
units.
An interlock circuit must be used if an
exhaust air unit (e.g. extractor hood, ex
tractor fan etc.) is installed in the rooms
which form part of the interconnected
combustion air supply for the Vitodens
100 boiler.
H Connection of a DHW circulation pump.
H Connection of a heating circuit pump
(staged).
H Connection of a central fault indicator.
Accessories
2
copper.
III
IP 30
20 to +40 °C
20 to +65 °C
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 100Wb1