Bellfires Derby Installation Instructions And Instructions For Use page 87

Gas fires with closed combustion system
Table of Contents

Advertisement

Bellfires
Model
Country
Product identification no
Type of appliance under CE-norm
Category of appliance
Nominal heat input (Gross calorific value) : 8.0 kW
Nominal heat output
Efficiency class
NOx-class
Gas rate (max.)
Supply pressure
Burner pressure (max.) Hot
Burner pressure (max.) Cold
Burner pressure (min.)
Gas regulator block (hand control)
Gas regulator block (remote control)
Main burner
Primary air inlet main burner
Main burner injector
Pilot light burner
Pilot light burner injector
Gas connection
Concentric flue system
Batteries remote control
- Receiver
- Hand-transmitter
(*)
: When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible.
Heat changing surface: Entire front of the appliance.
Instructions for use and installation instructions
: RETRO BELL SMALL
RETRO BELL SOLO
: GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland
: 0063BL5625
: C
/ C
11
31
: I
Natural gas G20
2H
: 5.8 kW
: 2 (80%)
: 5
3
: 0.76 m
/hr.
s
: 20.0 mbar
: 17.0 mbar(*)
: 16.2 mbar(**)
: 2.0 mbar
: BM 733-234484
: Mertik GV 34 / GV 60
: IGP
: 1x Ø15.0 mm
: no 18 / 560
(= 7x Ø0.891 mm)
: SIT 0.145.019
: no 36 (SIT 0.977.091)
: 3/8" G / Ø12 mm
: Ø100 mm - Ø150 mm
: 4x 1.5V AA
: 1x 9V block
English
: 0063BL5625
: C
/ C
11
31
: I
Propane G31
3P
: 7.5 kW
: 5.1 kW
: 2 (75%)
: 5
: 570 gr/hr.
: 37.0 mbar
: 29.2 mbar
: 29.2 mbar
: 5.0 mbar
: BM 733-234484
: Mertik GV 34 / GV 60
: IGP
: 2x Ø25.0 mm
: no 18 / 220
(= 7x Ø0.549 mm)
: SIT 0.145.019
: no 23 (SIT 0.977.150)
: 3/8" G / Ø12 mm
: Ø100 mm - Ø150 mm
: 4x 1.5V AA
: 1x 9V block
88

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents