Figure 4: Gas regulating block; Operating Knob in ON-position
Possible error messages:
*
Long beeps (0.8 secs on, 0.2 secs off) during ignition:
Receiver batteries need changing soon (having heard this signal, the
appliance can be ignited another ten times approximately).
*
5 second unbroken tone:
Error. For example, one of the cables may not be properly connected,
the "O I" switch is not in the "I" position.
*
5 short beeps (0.2 secs on, 0.2 sec off):
Ignition of the pilot light and main burner failed. Possible cause: air in
the pilot light pipe.
Important:
If the pilot flame goes out, then wait for
at least 5 minutes before repeating the
above procedure.
Setting the flame height/extinguishing the fire
After ignition, the burner automatically sets the flames to the maximum height.
Press the
button to lower the flames or turn off the burner. (To extinguish the fire
select "STAND BY".) (Touch the
Press the
button to raise the flames. (Touch the
gradually.)
Instructions for use and installation instructions
8 Wire
button to lower the flames gradually.)