Bellfires DERBY 3 Installation Instructions And Instructions For Use

Bellfires DERBY 3 Installation Instructions And Instructions For Use

Gas fires with closed combustion system

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE
DERBY 3
Gas fi res with closed combustion system
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
Read it carefully before installation and use of the
gas fi re and keep it in a safe place!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DERBY 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bellfires DERBY 3

  • Page 1 INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE DERBY 3 Gas fi res with closed combustion system Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re This document is an essential part of your gas fi re.
  • Page 3 Bellfi res English BELLFIRES GAS FIRES WITH CLOSED COMBUSTION SYSTEM: Derby 3 (DY3) Instructions for use and installation instructions...
  • Page 4 Bellfi res English Instructions for use and installation instructions...
  • Page 5: Table Of Contents

    Bellfi res English CONTENTS Page 1. WARRANTY TERMS ................. 2. INSTRUCTIONS FOR USE ............... 3. INSTALLATION INSTRUCTIONS .............. 4. MAINTENANCE ..................5. FAULTS ...................... 6. DISMANTLING / ASSEMBLING OF THE GLASS ........7. ELECTRICAL DIAGRAM ................8. DIMENSIONS .................... 9. TECHNICAL DETAILS/REGULATIONS ............ 10.
  • Page 6 Bellfi res English Instructions for use and installation instructions...
  • Page 7: Warranty Terms

    Bellfi res English WARRANTY TERMS Bellfi res gas fi re Warranty Bellfi res guarantees the quality of the supplied hearth and the quality of the materials used. This warranty runs for a period of twelve (12) months from fi rst use of the hearth and covers defects which are a result of construction faults or the failure of component parts.
  • Page 8 Bellfi res English Instructions for use and installation instructions...
  • Page 9: Instructions For Use

    Bellfi res English INSTRUCTIONS FOR USE INTRODUCTION Congratulations on your purchase of this modern Bellfi res gas fi re. This quality product will provide you with many years of enjoyment due to the fl ame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the fi...
  • Page 10 Bellfi res English Do not place easily-fl ammable materials, such as nylon clothing or fl ammable liquids, in the vicinity of the gas fi re. Ensure at all times that children and other people who are not aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision.
  • Page 11 Bellfi res English 2.4.1 Igniting the fi re • Open the gas supply valve in the gas pipe to the appliance. • Press in the control knob and turn it (clockwise) as far as possible. It is now in the “off”...
  • Page 12 Bellfi res English REMOTE CONTROL 2.5.1 General The appliance is opperated by radio remote control. This comprises a hand-held transmitter and a receiver. The receiver is part of the gas control block assembly. The receiver and the gas control block are behind the (white) panel door (operating unit) next to the appliance.
  • Page 13 Bellfi res English Set the display • Connect the batteries. By simultaneously pressing OFF and (small fl ame), can be switched from °F (and 12 hour clock) to °C (and 24 hour clock), or vice versa. • The display will automatically return to mode after some time, but you may immediately return to mode by pressing the OFF button.
  • Page 14 Bellfi res English Operating possibilities It is possible to use the remote control in 3 ways to operate the appliance: You can cycle through the menu with operating possibilities by repeatedly depressing the SET button. the selected starting time (P1 or P2 ) or stopping time (P1 or P2 ) is also shown.
  • Page 15 Bellfi res English Operating the night temperature thermostat (Appliance is in the stand-by position and the pilot light is burning.) Automatic temperature regulation of the pre-set night temperature. The room temperature is measured and compared with the pre-set night temperature. The fl ame height is automatically regulated so as to reach the pre-set night temperature.
  • Page 16 Bellfi res English Programming the timer: P1 and P2 by pressing the SET button briefl y. • Select the desired mode of operation • Press the SET button until P1 (heating period 1) and the time appear in the display. (The time indication fl ashes.) •...
  • Page 17 Bellfi res English Connection Piezo Igniter (only for MANual control) ON/OFF Switch Operating Knob 8-wire Receiver Jack Motor-Knob Microswitch (in maximum position) Figure 4: Gas regulating block; Operating Knob in ON-position • Possible error messages: * 3x short audio signal, audible when the motor-knob operates: Receiver batteries need changing soon (having heard this signal, the appliance can be ignited another ten times approximately).
  • Page 18 Bellfi res English • Press button (large fl ame) to increase the fl ame level and to turn on the burner from the stand-by position. (Pressing briefl y the (large fl ame) button gradually increases the fl ames to the high position.) Pressing the (large fl...
  • Page 19 Bellfi res English 1 Hand-held transmitter: * Open the cover on the back of the transmitter. * Carefully remove the 9V battery and disconnect it from the contact. Do not pull the wires! * Connect the new battery and replace in the battery compartment. Close the cover. 2 Receiver: * Carefully pull the receiver assembly out of the compartment behind the (white) panel door.
  • Page 20 Bellfi res English Igniting the fi re • Open the gas supply valve in the gas pipe to the fi re. • Switch the “O I” switch on the gas regulating block to the “I” position. • Turn the motor-knob on the gas regulating block completely to the right, in the OFF position.
  • Page 21 Bellfi res English 2.6 USING THE APPLIANCE FOR THE FIRST TIME The gas fi re is coated with a lacquer layer resistant to high temperature. During the fi rst hours of operation, the burning in of the lacquer may result in an unpleasant smell. This is harmless, however.
  • Page 22: Installation Instructions

    Bellfi res English INSTALLATION INSTRUCTIONS 3.1 GENERAL The gas fi re must be positioned and connected as a “room sealed system” (balance fl ue) appliance by a “Gas Safe Register” registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations”...
  • Page 23 Bellfi res English The appliance can be fi tted with a convection package as an optional extra. This is a “convection jacket” (convection casing) for around (or above) the appliance, two fl exible aluminium pipes and two built-in convection vents. This enables hot air to be circulated into the room.
  • Page 24 English OPTIONS AND ACCESSORIES The following options and accessories can be supplied by your dealer: Part no Option 3..Convection package Derby 3 3..• 1x Convection casing 312829 • 1x Convection set General 3..Set of high adjustable feet (4 pieces) 3..
  • Page 25 Bellfi res English PREPARATION FOR INSTALLATION The following preparation must be carried out before the gas fi re can be installed. 3.5.1 Instructions for positioning the outlet 3.5.1.1 Positioning the outlet for correct operation: Roof-mounted outlet: >0.5 m Figure 6: Roof-mounted outlet This must be positioned at least 0.5 m from the roof edge;...
  • Page 26 Bellfi res English 3.5.1.2. Positioning the outlet to avoid affecting the surrounding area All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives. “Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A.
  • Page 27 Bellfi res English Wall-mounted outlet: To avoid adverse effects Distance: outlet - A, B or C At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet. On a wall - general. (*) Above the outlet: >2 m Below the outlet:...
  • Page 28 Bellfi res English GENERAL SERVICES 3.6.1 The Fume Channel/Combustion Air Intake The combined fume channel and combustion air intake requires one of the following concentric fl ue system confi gurations. Important: Due to the high temperature of the outer walls (approx.
  • Page 29 Ø100-Ø150 mm Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Derby 3 Width: Width: 4.0 - 12.0 m B = 50 mm B = 80 mm Figure 9: Vertical roof-mounted outlet without bend...
  • Page 30 Ø100-Ø150 mm Ø130-Ø200 mm Width: Derby 3 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m B = 40 mm (*) : (Y ) : X > 2 : 1 (Vertical to horizontal ratio (or 45°...
  • Page 31 Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Derby 3 Width: Width: 4.0 - 12.0 m B = 50 mm B = 80 mm Figure 11: Vertical chimney outlet using an existing lined chimney (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
  • Page 32 Ø100-Ø150 mm Ø130-Ø200 mm Width: Derby 3 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m B = 40 mm (*) : (Y ) : X > 2 : 1 (Vertical to horizontal ratio (or 45°...
  • Page 33 Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Derby 3 Width: Width: 4.0 - 12.0 m B = 50 mm B = 80 mm Figure 13: Vertical chimney outlet using an existing unsound lined chimney or when no chimney liners are present (Flexible Ø100 mm / Ø150 mm)
  • Page 34 Ø100-Ø150 mm Ø130-Ø200 mm Width: Derby 3 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m B = 40 mm (*) : (Y ) : X > 2 : 1 (Vertical to horizontal ratio (or 45°...
  • Page 35 (min.-max.) on appliance is Ø130-Ø200 mm 2.0 - 3.0 m 0 - 0.6 m Derby 3 3.0 - 4.0 m 0 - 1.6 m Figure 15: Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION...
  • Page 36 (min.-max.) on appliance is Ø130-Ø200 mm 0.5 - 1.0 m 0 - 0.6 m Derby 3 1.0 - 2.0 m 0 - 2.6 m Figure 16: Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION...
  • Page 37 Ø130-Ø200 mm 0.5 - 3.0 m 0 - 2.6 m Width: B = 40 mm Derby 3 0.5 - 3.0 m 2.6 - 4.6 m Figure 17: Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION...
  • Page 38 0 - 0.6 m 0.5 - 1.0 m 0 - 0.5 m 0 - 0.5 m 0 - 0.6 m Derby 3 1.0 - 3.0 m 0 - 1.0 m 0.5 - 2.0 m 0 - 0.6 m 1.0 - 3.0 m 0 - 3.0 m...
  • Page 39 (min.-max.) on appliance is Ø130-Ø200 mm 0 - 0.5 m 0 - 0.6 m Width: B = 40 mm Derby 3 0.5 - 3.0 m 0 - 3.6 m Width: B = 50 mm 0.5 - 3.0 m 3.6 - 8.6 m...
  • Page 40 Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI. Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI. AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm...
  • Page 41 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX Twin-wall balanced fl ue elbow 45°, 302298 incl. 302295 Vertical (roof) termination kit, L = 1360 mm (vertical), incl. 302212 Adjustable roof fl ashing. Roof pitch 20° - 45° (**), with lead fl...
  • Page 42 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302189 Ceiling plate for transition Ø100 mm / Ø150 mm rigid - Ø100 mm (fl ex.). 302278 Stainless steel adapter piece (100) from fi re to fl exible, Ø100 mm external (rigid) x Ø107 mm internal...
  • Page 43 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302189 Concentric pipe with gauging orifi ce, L = 165 mm, incl. 302278 90° concentric bend with inspection panel, incl. 302279 Universal wall / fl oor support Ø150 mm...
  • Page 44 Bellfi res English AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm BELLFIRES Color(*) Application ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302319 Concentric reduction of Ø130 / Ø200 mm Ø100 / Ø150 mm 302308 Twin-wall balanced fl...
  • Page 45 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302311 : Stainless steel locking band Ø200 mm, quick-fastening 302248 : Silicone seal Ø200 mm 302251 : Wall strap 302250 Set of ceiling fi nishing plates /...
  • Page 46 Bellfi res English AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm POUJOULAT FIG. ART. / DESCRIPTION ORDER 37100403 Twin-wall balanced fl ue pipe, L = 250 mm 37100404 Twin-wall balanced fl ue pipe, L = 450 mm 37100405 Twin-wall balanced fl...
  • Page 47 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 30° 37100411 Twin-wall balanced fl ue elbow 15° 37100401 37100654 Vertical (roof) termination kit, L = 140 mm 45150171 Roof fl ashing, suitable for a brick roof, with a roof pitch of 15°- 30°...
  • Page 48 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 45150169 Roof fl ashing for existing chimney or fl at roof 37100610 Horizontal (wall) termination kit, L = min. 365 mm / max. 585 mm 45150076 Stainless steel locking band Ø150 mm, quick-fastening 45150072 Wall strap, Ø150 mm...
  • Page 49 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 45150165 Roof support, (universal) Ø150 mm 45150081 Floor support, (universal) Ø150 mm 37100611 Adapter: Bellfi res Ø100-150 mm Poujoulat PGI Ø100-150 mm (Appliance 100/150 Poujoulat PGI 100/150) 37100614 Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø100-150 mm (Appliance 130/200 Poujoulat PGI...
  • Page 50 Bellfi res English AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm POUJOULAT FIG. ART. / DESCRIPTION ORDER 37130403 Twin-wall balanced fl ue pipe, L = 250 mm Twin-wall balanced fl ue pipe, 37130404 L = 450 mm Twin-wall balanced fl...
  • Page 51 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION NOR. ORDER Twin-wall balanced fl ue elbow 30° 37130411 Twin-wall balanced fl ue elbow 15° 37130401 37130610 Horizontal (wall) termination kit, L = min. 425 mm / max. 585 mm 45200076 Stainless steel locking band Ø200 mm, quick-fastening 45200072 Wall strap, Ø200 mm...
  • Page 52 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 37130407 Concentric pipe with inspection opening, L = 250 mm 45200165 Roof support, (universal) Ø200 mm 45200081 Floor support, (universal) Ø200 mm 37130615 Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø130-200 mm (Appliance 130/200 Poujoulat PGI 130/200)
  • Page 53 Bellfi res English AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm ONTOP FIG. ART. / DESCRIPTION ORDER USA 10 Adapter for Bellfi res appliances with Ø100-Ø150 mm concentric connection US 25 10 Twin-wall balanced fl ue pipe, L = 250 mm US 50 10 Twin-wall balanced fl...
  • Page 54 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 15° USB 15 10 USDVC2 10 Vertical (roof) termination kit, L = 375 mm, incl. USSR 10 Storm collar Ø150 mm USLS 10 Adjustable roof fl ashing. Roof pitch 20°...
  • Page 55 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USKB 10 : Locking band, quick-fastening USAB 10 : Cover band, screw-fastening USMB 10 Wall strap, adjustable USEB 10 Fitting bracket USCP 10 Set of ceiling fi nishing plates / Fire stops / Centring plates USDQ 10 Roof support...
  • Page 56 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USSAN2 10 Bottom renovation set USKBS 10 Locking band, screw-fastening USI 10 Concentric pipe with inspection panel, L = 250 mm USEM 10 Concentric pipe with gauging orifi ce, L = 150 mm USBI 10 90°...
  • Page 57 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USVG 10 13 Concentric reduction of Ø100-Ø150 mm Ø130-Ø200 mm AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm ONTOP FIG. ART. / DESCRIPTION ORDER USA 13 Adapter for Bellfi...
  • Page 58 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 45° USB 45 13 Twin-wall balanced fl ue elbow 30° USB 30 13 Twin-wall balanced fl ue elbow 15° USB 15 13 USDVC2 13 Vertical (roof) termination kit, L = 375 mm, incl.
  • Page 59 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USDP 13 Roof fl ashing for existing chimney or fl at roof USDPAL 13 Roof fl ashing - Aluminium for existing chimney or fl at roof USDHC4 13 Horizontal (wall) termination kit, L = 475 mm (horizontally adjustable)), incl.
  • Page 60 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USDQ 13 Roof support USSAN 13 Renovation set USSAN1 13 Top of renovation set USSAN2 13 Bottom renovation set USKBS 13 Locking band, screw-fastening USI 13 Concentric pipe with inspection panel, L = 250 mm USEM 13 Concentric pipe with gauging orifi...
  • Page 61 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USBI 13 90° concentric bend with inspection panel Rosette smooth Ø200 mm USR 13 Wall plate large Ø200 mm, 350 mm USMPG 13 Spacer bracket ASAH 13 Concentric reduction of Ø130-Ø200 mm USVG 13 10 Ø100-Ø150 mm •...
  • Page 62 Bellfi res English 3.6.3 Gas connection Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit): The gas connection is situated where the operating unit is built in near to the appliance. Use only gas piping with a minimum diameter of 1/2” and a shut-off valve. 3.6.4 Operating unit If the appliance is fi...
  • Page 63 Bellfi res English Never position the appliance directly against the rear wall, but always place an nonfl ammable insulation plate, at least 12 mm thick, between the appliance and the rear wall, with free space on either side of 2 cm. (Total ± 5 cm.) The rear wall must be made of nonfl...
  • Page 64 Bellfi res English Figure 21: Appliance installed in ventilated chimney breast Horizontal outlet of the fl ue gas exhaust /combustion air supply via the wall. Fitted with the options / accessories: • convection package (= convection casing and 1x convection set) •...
  • Page 65 Bellfi res English Figure 22: Appliance installed in ventilated chimney breast Vertical outlet of the fl ue gas exhaust / combustion air supply via the roof. Fitted without convection package Inlet opening (appliance) convection air Inlet opening (grate) (chimney breast) convection air Natural convection in the chimney breast Outlet opening (grate) (chimney breast) convection air (2x) Concentric fl...
  • Page 66 Bellfi res English When fi tting the appliance, it can be levelled with the adjustable feet. These adjustable feet can be reached via the openings (4x), after removing the protec- tive covers, in the corners of the fl oor of the combustion chamber. The fl...
  • Page 67 Bellfi res English Position the gas supply pipe such that it can be easily mounted after installation. Because the control system is outside the appliance, the gas pipe must lead to where the operating unit (built in), the gas regulating block (and the receiver) assembly are fi...
  • Page 68 Bellfi res English 3.7.1 Connecting the gas Important: During gas connection, take care not to twist the gas regulating block. Make sure that both the gas regulating block and the supply pipes are not subjected to stresses. Appliance with operation in the separate operating unit (built in or otherwise):. •...
  • Page 69 Bellfi res English Remote control Gas regulating block and receiver in operating unit Gas regulating block Gas supply connection 3/8” - Ø12 mm insertion Burner piping connection Ø8 mm insertion Thermocouple connection M 10x1 mm insertion Pilot light piping connection Ø4 mm insertion Receiver Piezo cable connection Figure 24: Remote control: Gas regulating block and receiver in operating unit...
  • Page 70: Remote Control

    Bellfi res English Remote control The photo below shows how the piping for a remote control gas regulating block must be fi tted. Pilot Gas Adjustment Maximum Rate (with Screwdriver) Adjustment Screw Motor-knob Operating-Knob (Tab 2,8 x 0,8 mm) Connection piezo cable (Hand Control) Side-inlet Thermo Unit Connection...
  • Page 71 Bellfi res English Operating-Knob Motor-knob (Remote control ↔ Hand control) Connection Microswitch Piezo Igniter (Hand control) Piezo Igniter (Hand control) “O I” Switch Connection 8-Wire Receiver Jack Pilot Gas Figure 26: Gas regulating block Remote control Hand control Gas regulating block in operating unit The photo below shows how the piping for a hand control gas regulating block must be fi...
  • Page 72 Bellfi res English Appliance with operation in the separate operating unit (built in or otherwise). • Gas control block and piping supplied as an pre-assembly. First detach the bracket with the gas control block from the appliance. Fit the separate control unit max. 50 cm from the appliance. Fit the receiver in the top of the control unit.
  • Page 73 Bellfi res English The optional mantle iron is intended for supporting the brickwork above the hearth. The mantle iron must rest on the brickwork on both sides so that upward building is possible. The brickwork therefore must not rest on the fi replace; there must be approx. 3 mm clearance in connection with the weight.
  • Page 74 Bellfi res English Remove the glass according to the instructions in chapter 6; DISMANTLING / ASSEMBLING OF THE GLASS. 3.7.5.1 Ceramic log set + chips of wood + embers + vermiculite granules 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings.
  • Page 75 4 Place the logs on the burner: Natural gas-burner Propane / Butane-burner Appliance see fi gure: see fi gure: Derby 3 Keep the burner orifi ces unblocked !!! 5 Place the chips of wood around the burner. Instructions for use and installation instructions...
  • Page 76 Bellfi res English Logs: Log no Log no Log no Log no Log no Log no Log no Log no Instructions for use and installation instructions...
  • Page 77 Embers must not be placed next to the pilot light burner Keep the burner orifi ces unblocked! Figure 27: Log set Derby 3 Position natural gas burner Embers must not be placed next to the pilot light burner Keep the burner orifi ces unblocked!
  • Page 78 2 Spread the pebbles over the whole burner bed (burner and grid around the burner). Make sure that the pilot light remains free. Derby 3 see fi gure 30 IMPORTANT: Open area, in order to ensure free accessibility of the pilot fl...
  • Page 79 Keep the burner orifi ces unblocked! Figure 30: Marble pebbles Derby 3 Position natural gas and propane/butane burner Important: • Do not place any marble pebbles in front of the pilot light.
  • Page 80 Bellfi res English Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi...
  • Page 81: Maintenance

    Bellfi res English MAINTENANCE 4.1 ANNUAL MAINTENANCE It is essential that the appliance, the complete concentric fl ue system (where possible) and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
  • Page 82: Faults

    Bellfi res English FAULTS Possible reasons for the gas fi re going out are: • The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 3.6. • An incorrect “fl ue gas restriction plate” is fi tted. •...
  • Page 83: Dismantling / Assembling Of The Glass

    Bellfi res English DISMANTLING / ASSEMBLING OF THE GLASS 6.1 DERBY 3 FLOATING FRAME Dismantling of the glass: - Derby 3 Floating Frame - Use the hook supplied (see photo) for opening the frame and the glass. Note ! :...
  • Page 84 Bellfi res English stud (right) - Detail of the stud (right). Place paperboard on the chimney breast, under the frame. This helps prevent damage. - Carefully tilt the frame and the window - Take hold of the frame and the glass forwards.
  • Page 85 Bellfi res English - Frame and glass are now removed from the appliance. Assembling of the glass: The assembly of the glass takes place in reverse order. Important: • Check whether the frame is properly positioned underneath in the 2 holes of the front. •...
  • Page 86 Bellfi res English 6.2 DERBY 3 HIDDEN DOOR Dismantling of the glass: - Derby 3 Hidden Door. - Use the hook supplied for opening the frame (including glass). - Use the hook to pull the frame at the top forward and hold the frame fi rmly.
  • Page 87 Bellfi res English - With the hook, pull the thin, metal spring strips on the top left and right from the studs on the frame. Note ! : When loosening the frame and after it has been loosened, support it with your hand to prevent it falling forward ! - Carefully tilt the frame and the glass forwards at the top.
  • Page 88 Bellfi res English Assembling of the glass: The assembly of the glass takes place in reverse order. Important: • Check whether the frame is properly positioned underneath in the 2 holes of the front. • Check whether the frame is placed in the middle of the front. •...
  • Page 89: Electrical Diagram

    Bellfi res English ELECTRICAL DIAGRAM Operating-Knob Motor-knob Gas regulating block “black” Thermo - “O I” Switch current “red” Interrupter Block 8 Wire Connecting Cable cable 2 cable 1 Thermo- Antenna Ignition cable couple “red” “yellow” SPARK RECEIVER SPARK SW TC ON/OFF Switch Thermocurrent interrupter Block...
  • Page 90: Dimensions

    Bellfi res English DIMENSIONS DERBY 3 8.1.1 DERBY 3 - Hidden Door Instructions for use and installation instructions...
  • Page 91 Bellfi res English 8.1.2 DERBY 3 - Floating Frame Instructions for use and installation instructions...
  • Page 92 Fitted with the options: - Convection casing - High adjustable feet 8.2.1 DERBY 3 - Hidden Door * With the high adjustable feet (option), the appliance can be installed till 350 mm above the fl oor. Instructions for use and installation instructions...
  • Page 93 Bellfi res English 8.2.2 DERBY 3 - Floating Frame * With the high adjustable feet (option), the appliance can be installed till 350 mm above the fl oor. Instructions for use and installation instructions...
  • Page 94 Bellfi res English OPERATING UNIT Instructions for use and installation instructions...
  • Page 95: Technical Details/Regulations

    National installation regulations: Gas safety installation and use regulations 1984 plus all relevant safety and building regulations concerning fi re installation Model : DERBY 3 Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identifi cation no...
  • Page 96 Bellfi res English Model : DERBY 3 Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Batteries remote control - Receiver : 4x 1.5V AA : 4x 1.5V AA - Hand-transmitter : 1x 9V block : 1x 9V block...
  • Page 97: Replacement Parts List

    All parts listed in this manual may be ordered from a Bellfi res dealer. Article no Description 325822 Main burner Derby 3 Natural gas G20/G25 1x Ø18 mm 310805 Main burner Derby 3 Butane/Propane G30/G31 2x Ø20 mm...
  • Page 98 Nut; Ø8 mm, compression elbow main burner 326054 Olive; Ø8 mm, compression elbow main burner 329701 Glass Derby 3 Hidden Door (642 x 796 x 4 mm) 329700 Glass Derby 3 Floating Frame (648.5 x 788 x 4 mm) Instructions for use and installation instructions...
  • Page 99 Bellfi res English Logs - Chips of wood - Embers - Vermiculite granules - Marble pebbles Instructions for use and installation instructions...
  • Page 100: Disposal Of Packaging And Appliance

    Bellfi res English DISPOSING OF PACKAGING AND APPLIANCE The appliance comes in recyclable packaging. This can include: • Cardboard • Wood • Plastic • Paper Such materials must be disposed of responsibly, in line with local regulations. Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
  • Page 101 Bellfi res English Instructions for use and installation instructions...
  • Page 102 INTERFOCOS B.V. HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E-mail: info@interfocos.nl Internet: www.interfocos.com 01 - 150311 - 329739...

Table of Contents