Focal Point HANNINGTON BRASS F500310 Installation & User's Instructions

Inset decorative gas fire

Advertisement

INSTALLATION & USER INSTRUCTIONS
Focal Point Fires plc.
Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e : sales@focalpointfires.co.uk
Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Focal Point Fires plc. You are not per-
mitted to copy or adapt any of the content without the
prior written permission of Focal Point Fires plc.
INSET DECORATIVE GAS FIRE
MODELS COVERED BY THESE INSTRUCTIONS
HANNINGTON BRASS
HANNINGTON BLACK
HANNINGTON BRASS
F500310
F500311
All instructions must be handed to the user for
Revision A - 11/10
1
HANNINGTON BLACK
safekeeping.
©
2010 Focal Point Fires plc.
GB IE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HANNINGTON BRASS F500310 and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point HANNINGTON BRASS F500310

  • Page 1 Please note : Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is owned by Focal Point Fires plc. You are not per- All instructions must be handed to the user for mitted to copy or adapt any of the content without the safekeeping.
  • Page 2: Table Of Contents

    • Consult ALL instructions before installation and use of this appliance. • This appliance is intended for decorative purposes. • This appliance is free from any asbestos material. • Refractories and fuel bed are constructed from ceramic fibre. © © 2010 Focal Point Fires plc. 2010 Focal Point Fires plc.
  • Page 3: Appliance Data

    F. Non-combustible hearth must be a minimum of 50mm in height, or be sur- surrounded by a raised edge or fender rounded by a 50mm high fender. 50mm high. © 2010 Focal Point Fires plc.
  • Page 4: Ventilation

    8mm external diameter. The appliance is factory fitted with an inlet restrictor elbow. Use a minimum length of 8mm pipe, less than 1.5m where possible, as a long run of pipe may cause an unacceptable drop in the supply pressure. © 2010 Focal Point Fires plc.
  • Page 5: Testing & Commissioning

    In the event that the burner pressure is not in accordance with the figures stated in the data section of these instructions, the appliance must not be commissioned, and the manufacturer should be contacted for guidance. © 2010 Focal Point Fires plc.
  • Page 6: Flue Spillage Monitoring System

    9. Ensure the injector is aligned squarely with the venturi tube. Re-assemble and re-fit the burner tray. 10. Re fit and replace the ceramics, using genuine spares where necessary. 11. Re-fit the decorative front. © 2010 Focal Point Fires plc.
  • Page 7: Troubleshooting Guide

    Fire smells when first lit or in use Newness smell from brand new appliance. Spillage occurring. Carry out spillage test and rectify any problems. Low temperature sealants or combustible materials used in incorrect positions. © 2010 Focal Point Fires plc.
  • Page 8 Any combustible side walls must be at least 500mm to the side of the radiant heat source. As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper) positioned too close to the appliance may discolour or scorch. © 2010 Focal Point Fires plc.
  • Page 9 2. The front edge of the matrix should sit snugly behind the back edge of the burner rails as shown in figure 3. Do not fit the matrix on top of the burner rails. Figure 3 Correct Incorrect © 2010 Focal Point Fires plc.
  • Page 10 IMPORTANT : The fire is designed to operate correctly with the coals supplied when assembled according to the instructions. Never add to the sixteen coals, or change them for a different type. Never throw rubbish or other matter onto the coal bed. © 2010 Focal Point Fires plc.
  • Page 11 Part number Burner assembly - complete TRAY014 Firefront - brass F800045 Firefront - black F800048 Main gas valve F730066 F730006 Injector F730046 Ceramic coal matrix F780007 Front coal strip F780008 Pack of 16 Coals F550038 © 2010 Focal Point Fires plc.
  • Page 12 As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice. Note : Gas Safe registered operatives are the only class of person considered as competent by the HSE under the Gas Safety (Installation and Use) Regulations 1998. © 2010 Focal Point Fires plc.