Integrated Peripherals - Teknor Industrial Computers TEK-CPCI-1000 Technical Reference Manual

Table of Contents

Advertisement

TEK-CPCI-1000 Technical Reference Manual

12.1.9 Integrated Peripherals

Option
BIOS
Default
IDE HDD Block Mode
Dis.
PCI Slot IDE 2nd
En.
Channel
On-Chip
En.
Primary/Secondary
PCI IDE
IDE
Auto
Primary/Secondary
Mast./Slave PIO
USB Controller and
Dis.
Keyboard
Onboard FDC
En.
Controller
Onboard
Auto
Serial Port 1/2
UART2 Mode
Stand
ard
Duplex Select
Half
TxD, RxD Active
Hi/Lo
Onboard Parallel Port
378/IR
Q7
Parallel Port Mode
Nornal
ECP Mode Use DMA
3
Setup
Possible
Default
Settings
En.
En., Dis.
Block mode is also called block transfer, multiple commands, or
multiple sector read/write. If your IDE hard drive supports block
mode (most new drives do), select Enabled for automatic detection
of the optimal number of block read/writes per sector the drive can
support.
En.
En., Dis.
You may separately disable the second channel on an IDE interface
installed in a PCI expansion slot.
En.
En., Dis.
The integrated peripheral controller contains an IDE interface with
support for two IDE channels. Select Enabled to activate each
channel separately.
Auto
Mode 0, Mode
The four IDE PIO (Programmed Input/Output) fields let you set a PIO
1, Mode 2,
mode (0-4) for each of the four IDE devices that the onboard IDE
Mode 3, Mode
interface supports. Modes 0 through 4 provide successively
4, Auto
increased performance. In Auto mode, the system automatically
determines the best mode for each device.
Dis.
En., Dis.
Select Enabled if your system contains an Universal Serial Bus
(USB) controller and you have USB peripherals.
En.
En., Dis.
Select Enabled if your system has a floppy disk controller (FDC)
installed on the system board and you wish to use it. If you install an
add-in FDC or the system has no floppy drive, select Disabled in this
field.
Auto
Dis.,
Select a logical COM port name and matching address for the first
COM1/3F8,
and second serial ports.
COM2/2F8,
COM3/3E8,
COM4/2E8,
Auto
Stand
Standard,
Select a communication protocol for Serial Port 2: Standard for
ard
IrDA, ASK-IR
normal operation, IrDA or ASK-IR for infra-red operation.
Half
Half, Full
Half for one communication at a time, Full for simultaneous
communication.
Hi/Lo
Hi/Hi, Hi/Lo,
Determines whether the transmit signal (TxD) and the receive signal
Lo/Hi, Lo/Lo
(RxD) are active high (Hi) or active low (Lo).
378/IR
378/IRQ7,
Select a logical LPT port name and matching address for the
Q7
physical parallel (printer) port.
278/IRQ5,
3BC/IRQ7,
Dis.
ECP+
ECP+EPP1.9,
Select an operating mode for the onboard parallel port. Select ECP
EPP1.
Normal,
or EPP unless you are certain both your hardware and software
9
does not support EPP or ECP mode.
EPP1.7+SPP,
ECP+EPP1.7,
SPP,
EPP1.9+SPP,
ECP
3
1, 3
Select a DMA channel for the port.
12-12
Description

Advertisement

Table of Contents
loading