The LED lights during the IDD is executing a command. However,
in same commands, the lighting time is only an instant. Therefore,
it seems that the LED blinks or the LED remains off.
5.4.2

Checking connection

When the initial operation is checked normally after power is turned on, check that the IDD is
connected to the loop from the host system. Although checking the connection depends on the
structure of the host system, this section describes the general procedures.
(1)
Checking procedure
Issuing the commands and determining the end status depends on the start mode of the spindle
motor and unit attention report mode (specified with setting terminal). Figure 5.1 shows the
recommended checking procedure for the mode that the motor starts when power is turned on.
Figure 5.2 shows for the mode that the motor starts by the START/STOP UNIT command. In
these recommended checking procedures, following items are checked.
Note:
Following steps a) to e) correspond to a) to e) in Figures 5.1 and 5.2.
a)
Issue the TEST UNIT READY command and check that the IDD is connected correctly
to the loop and the initial operation after power is turned on ended normally. The
command issue period of the TEST UNIT READY command shall be more than 20 ms.
b)
To control starting of the spindle motor from the host system, issue the START/STOP
UNIT command to start the spindle motor.
c)
Check the loop operations with the WRITE BUFFER and READ BUFFER commands.
d)
Start the IDD self-diagnostic test with the SEND DIAGNOSTIC command and check
the basic operations of the controller and disk drive.
5 - 6
IMPORTANT
C141-E078-02EN