M Design 850 V / 550 V GOLD GAS Instructions For Installation And Use Manual

Hide thumbs Also See for 850 V / 550 V GOLD GAS:

Advertisement

LUNA 850 V / 550 V GOLD GAS
LUNA 850 DV / 550 DV GOLD GAS
INSTRUCTION FOR INSTALLATION AND USE
English 06-2012
Passion for fire

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 850 V / 550 V GOLD GAS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M Design 850 V / 550 V GOLD GAS

  • Page 1 LUNA 850 V / 550 V GOLD GAS LUNA 850 DV / 550 DV GOLD GAS INSTRUCTION FOR INSTALLATION AND USE English 06-2012 Passion for fire...
  • Page 2 R E S U L T O F I N C O R R E C T I N S T A L L A T I O N M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 3: Table Of Contents

    EXAMPLES WITH OR WIHOUT FINISHING FRAME .. 32-33 FINISHING FRAME ............... 14. SPARE PARTS ................35-36 15.GUARANTEE ................16. IDENTIFICATION BOARDS ..........38-39 17. CE CERTIFICATION ............. 39-40 M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 4 IF SOME DUST OR WASTE IS SEEN ON THE WINDOW ( INSIDE AND OUTSIDE ), CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 5: General Remarks

    This appliance has been programmed and factory sealed. The sealed parts cannot be modified. The appliance may therefore also be installed in watertight accommodation and accommodation equipped with mechanical ventilation. It constitutes ambient heating even in accommodation equipped with a closed ventilation system. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 6: Installing The Fireplace

    The maximal height as from the ground to the 4th side frame is 45 cm. A min = 3,5 cm pic. 2 B = 14,5 cm pic. 1 C min = 18 cm pic. 3 M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 7: Gas Connection

    130°C. The passage of the front panel cowl in the external wall must be filled in using silicone mastic. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 8 Restriction HR+ (as from 3m) LUNA 850 V / 550 V Ø 60 LUNA 850 DV / 550 DV Ø 60 FIG. 1 M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 9 It is obligatory to use the sanitation set USSAN with placing. FIG. 2 This USSAN piece must be saeled at the roof. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 10 A+ ”USVK13” +4m ---------- 850 DV / 550 DV 1,25m wall exit A+ ”USVK13” +3m ---------- USVK13 REDUCTION 200/130 →150/100 FIG. 4 M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 11 OF OUTLET. IT IS EVEN BETTER, WHEN POSSIBLE, TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING. ONLY THE OUTLET MUST BE INSTALLED LIKE PIC. 6 ( TO AVOID RAIN DROPS IN TUBE ) M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 12 CAUTION : if the vertical lenght is over 3 meter longer than the horizontal lenght, you will Ø 60. need to place a reduction ring of M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 13: Insulation And Finishing

    Please pay attention to leave approx. 2 mm inbetween the finishing frame and maconry ( see p.17 , mounting a 3-sided frame ) REFERENTIAL DISTANCES IN REGARDS TO FINISHING THE MANTLEPIECE A very essential point when setting up the Luna Gold is that the distance has to be respected inbetween fireplace and the finishing material for the mantlepiece such as marble, gipsum,...
  • Page 14: Convection Current

    ( dia. 150 mm). It is obligatory to open at least 2 hot air vents ( for the LUNA 1600 you must open 4) at the top of the appliance. For the purposes of the installation of these ducts it is best to go vertically upwards first for at least 1m and then to change di- rection, making a rather wide bend and avoid using a flue terminal grid with a small clearance because the speed loss that this causes reduces the efficiency of the hot air vents.
  • Page 15 Design Grill ( OUTLET ) 4 dm² 2 dm² INLET INLET M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 16 EVERY OPENING YOU MAKE MUST BE CONNECTED WITH A FLEXIBLE TUBE dia.150MM (see pic. below). THIS WILL AVOID THE HEATING OF THE ELECTRONIC PART OF THEAPPLIANCE. IN OTHER CASE YOU WILL HAVE ERRORCODE F02. Good Good M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 17: Mounting A 3 Sided Frame

    First remove the profile that is delivered with the fireplace ( pic. 1 ) The 3 sided frame consist of 3 parts and are assembled to the Luna ( pic. 2 ) Fixing to frame with the included screws ( pic.3 ) the 3 sides frame and his 3 parts pic.1...
  • Page 18: Positioning The Logs, Diamond, Sapphire And White Pebbles

    Put the little imitation coal pieces on the burner en here and there Put the big immitation coal pieces around the burner. around the big coal pieces. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 19: 850 V / 850 Dv

    LUNA 850V / 850DVGAS M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 20 LUNA 850V 850DV GAS M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 21 LUNA 850 V GAS / GAZ Only for 850V with two burners Seulement pour appareil 850V avec deux brûleurs en escaliers M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 22: 550 V / 550 Dv

    LUNA 550 V / 550 DV M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 23 LUNA 550 V / 550 DV M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 24: First-Time Use

    This enables the electronic system to run down from static electricity. • In the case where the burner goes out for any reason, wait for 3 minutes before relighting the furnace. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 25: Startpilot

    To switch off , turn the potentiometer to the left “off” and push once to extinguish the starpilot flame. Push a second time to swith off the whole fireplace. push button potentiometer knob M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 26: Specification Sheet

    0.20P3 0.20P3 Output (%) 87,1 Nominal load (KW) Output power (KW) Emission classification NOX Output category EC Fr/Re : front / rear M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 27 Output (%) Nom.Belasting / Charge nominale (KW) Nuttig vermorgen Puissance utile (KW) Klassement NOX-emmissie Classement d’émission NOX Cat. Rendement CE Catégorie rendement CE M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 28: Drawings

    850V with one burner ( saphir, diamon, white stones ) 850V with two burner ( woodset ) M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 29 LUNA 850 DV GOLD GAS connection gas on the left side M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 30 LUNA 550 V GOLD GAS connection gas on the left side M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 31 LUNA 550 DV GOLD GAS connection gas on the left side M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 32: Examples With Or Wihout Finishing Frame

    4 mm = thickness frame 2 mm = gap between frame and maconery Min. distance between appliance Min. 4cm and maconery : 4cm M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 33 Y = measurment from underneath 4th side frame till upper side frame above window Min. distance between appliance Min. 4cm (finishing size ) and maconery : 4cm M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 34: Finishing Frame

    4-sided frame X = 3,5 cm DETAIL Z onderlat / baguette X = 7 cm X = 10,5 cm M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 35: Spare Parts

    X = 850V, 550V, 14. SPARE PARTS M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 36 14. SPARE PARTS X = 850DV, 550DV M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 37: Guarantee

    4th side frame to see the number this is situated at the left side of the appliance. at the left side below the glass. M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 38: Identification Boards

    Vorschriften. Das Gerat ist nur in ausreichend belüfteten Räumen zu betreiben nationalen und lokalen Vorschriften. Das Gerat ist nur in ausreichend belüfteten Räumen zu betreiben M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 39 Vorschriften. Das Gerat ist nur in ausreichend belüfteten Räumen zu betreiben nationalen und lokalen Vorschriften. Das Gerat ist nur in ausreichend belüfteten Räumen zu betreiben M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 40: Ce Certification

    17. CE CERTIFICATION M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...
  • Page 41 M-DESIGN INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS...

Table of Contents