6.3 Pipe length and the elevation

The pipe length and refrigerant amount:
Model
All
ALL
ACP-09CH25AEF, ACP-09CH25AEG
ACP-12CH35AEF, ACP-12CH35AEG
ACP-18CH50AEF, ACP-18CH50AEG
ACP-09CH25AEF, ACP-09CH25AEG
ACP-12CH35AEF, ACP-12CH35AEG
ACP-18CH50AEF, ACP-18CH50AEG
ACP-24CH70AEG
Caution:
Capacity test is based on standard length and maximum allowance length is based on system
reliability.
Oil trap should be installed per 5-7 meters.
Connective pipe length
Less than 5m
More than 5m
Model
ACP-24CH70AEG
Air purging
Use vacuum pump
Use vacuum pump
Standard
length
17
www.fineprint.cn
Additional amount of
refrigerant
------------------
(Pipe length – 5) × 20g/m
Max.
Elevation
(m)
B (m)
5
8
5
10
5
10
Max.
Length
A (m)
20
25
20