5.3 Pipe length and the elevation

The pipe length and refrigerant amount:
Model
ACP-12CH35AERI/I
ACP-18CH50AERI/I
ACP-24CH70AERI/I
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.
ACP-12CH35AERI/O
+
ACP-18CH50AERI/O
+
ACP-24CH70AERI/O
+
Standard
Pipe size
length
Gas
Liquid
3/8''
1/4''
(Ф9.52)
(Ф6.35)
1/2''
1/4''
(Ф12.7)
(Ф6.35)
5/8''
3/8''
(Ф15.9)
(Ф9.52)
13
Max.
Max.
Elevation
Length
(m)
B (m)
A (m)
5
10
5
20
5
25
Additional
refrigerant
(g/m)
25
15
30
15
50
30