Reinstall Bottom Vent - KitchenAid 9760618 Installation Instructions Manual

36" (91.4 cm) classic commercial style dual fuel convection range for residential use only
Table of Contents

Advertisement

Available languages

Available languages

Adjust Flame Height
Adjust the height of top burner flames. The cooktop "low" burner
flame should be a steady blue flame approximately ¼" (0.64 cm)
high.
A
B
A. Low flame
B. High flame
The flame can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located directly
underneath the control knob.
A. Adjustment screw
If the "low" flame needs to be adjusted:
1. Remove the control knob.
2. Hold the knob stem with a pair of pliers. Use a small flat-
blade screwdriver to turn the screw located in the center of
the control knob stem until the flame is the proper size.
3. Replace the control knob.
4. Test the flame by turning the control from "LO" to "HI,"
checking the flame at each setting.
Check Operation of Oven Element
1. Turn oven selector to BAKE. Default temperature appears in
the temperature display.
2. Press ENTER. The first preheat light comes on when the oven
temperature begins to rise.
12
A
3. When the second preheat light comes on, open oven door
and hold hand above oven floor and feel for heat. Do not
touch oven floor. Press CANCEL and turn oven selector to
RESET.
Check Operation of Oven Broil Element
1. Close the oven door.
2. Turn oven selector to BROIL. "HI" will appear in the
temperature display.
3. Press ENTER. Look through oven window. The top element
should glow red, and heat should be radiating out of the door.
Press CANCEL and turn oven selector to RESET.
If oven does not operate:
Check that power supply is turned on.
Check that the range is plugged in and the circuit breaker has
not tripped or the household fuse has not blown.
Repeat start-up. If the oven still does not operate at this point,
contact your dealer or authorized service company for
assistance.
Install Burner Grates
Place burner grates over burner caps. The simmer plate may sit
on one of the grates or be stored for future use.

Reinstall Bottom Vent

1. Insert lower vent tabs into the slots on the front trim.
2. Push vent upward until the holes line up at top of vent.
3. Reattach the vent using the 4 screws.
A
A. Bottom vent
B. Reattach these screws.