Mitsubishi Electric JT-MC206GS-W-E User Manual page 12

Hand dryer
Hide thumbs Also See for JT-MC206GS-W-E:
Table of Contents

Advertisement

Error Display
(Motor error)
(Motor brush error)
(Temperature detection er-
ror (Power circuit board))
(Temperature detection er-
ror (Control circuit board))
(Control circuit board error)
Cause
Connector dis-
Check if the lead wire connectors between the motor and the
connection for the
power circuit board (JT-33P) are disconnected.
motor
Motor brush at the
Replace the blower (assembly).
end of its life
Motor lock
Check if the motor vanes are locked.
Blown thermal
Measure the resistance between the both ends of the motor lead.
fuse of the motor
If it is ∞ Ω, replace the blower (assembly).
Malfunction of
If no error is found after checking the above, replace the control
the control circuit
circuit board (JT-33M).
board (JT-33M)
Malfunction of
If the error persists after replacing the control circuit board (JT-
the power circuit
33M), replace the power circuit board (JT-33P).
board (JT-33P)
Unusually worn-
Replace the blower (assembly).
out motor brush
Motor brush at the
Replace the blower (assembly).
end of its life
Malfunction of
If the error persists after performing the above, replace the control
the control circuit
circuit board (JT-33M).
board (JT-33M)
Malfunction of
If the error persists after replacing the control circuit board (JT-
the power circuit
33M), replace the power circuit board (JT-33P).
board (JT-33P)
An abnormal
If the temperature on the power circuit board (JT-33P) rises due to
temperature has
the overuse, the hand dryer stops the operation.
been detected.
Leave it until the temperature falls, and then check if the error oc-
curs again.
Malfunction of
If the error persists after performing the above, replace the power
the power circuit
circuit board (JT-33P).
board (JT-33P)
An abnormal
If the temperature on the control circuit board (JT-33M) rises due
temperature has
to the overuse, the hand dryer stops the operation.
been detected.
Leave it until the temperature falls, and then check if the error oc-
curs again.
Malfunction of
If the error persists after performing the above, replace the control
the control circuit
circuit board (JT-33M).
board (JT-33M)
Malfunction of
Replace the control circuit board (JT-33M).
the control circuit
board (JT-33M)
Check Method and Remedy
─ 12 ─

Advertisement

Table of Contents
loading

Table of Contents