Mitsubishi Electric JT-S2AP-S-NE Instruction Manual

Mitsubishi Electric JT-S2AP-S-NE Instruction Manual

Jet towel hand dryer
Hide thumbs Also See for JT-S2AP-S-NE:

Advertisement

Quick Links

IFS Ltd t/a Intelligent Hand Dryers UK
www.intelligenthanddryers.com
0114 354 0047

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric JT-S2AP-S-NE

  • Page 1 IFS Ltd t/a Intelligent Hand Dryers UK www.intelligenthanddryers.com 0114 354 0047...
  • Page 2: Table Of Contents

    1511876HB7301 Hand dryer MODEL JT-S2AP-W-NE Heater Model JT-S2AP-S-NE Heater-less Model JT-S2A-W-NE Location of Model Name display Unit colour -W (White) ( Silver ) Location of power supply voltage display Single-phase 220 – 240V AC INSTRUCTION MANUAL For User ■ Read the manual thoroughly before using the unit to ensure it is used safely and correctly.
  • Page 3: Safety Precautions

    Safety Precautions The dangers arising from improper handling and the extents of the dangers are classifi ed and explained as shown below. The following may lead to death or Warning serious personal injury if handled incorrectly. Do not install in locations where they Do not modify or disassemble the unit.
  • Page 4 Safety Precautions - Continuation NOTE Do not use in the following locations. ● Outdoors  Locations where the temperature could be lower than 0 C.  Locations where there is a lot of dust. ● ● ● Locations where the temperature could be higher than 40 C.  Locations where there is a lot of condensation.
  • Page 5: Names Of Parts

    Names of Parts ※ Shaded areas in the fi gure indicate antibacterial material (excluding outlet nozzle areas). Main Unit Front panel Nozzle Sensor Air inlet Power light ※ Hand drying Front cover area ※ The front cover of JT-S2AP is not antibacterial. This information is based on REGULATION(EU) No 528/2012 MODEL NAME: JT-S2AP, JT-S2A Treated Article...
  • Page 6: How To Use The Unit

    How to use the unit ■ Turning the power on Turn the ground-fault circuit interrupter "ON". The power light (blue) turns on. ● ■ If not using for a long period Turn the ground-fault circuit interrupter "OFF". ■ How to use the unit Rub your hands together after the water is Hand detection area blown off...
  • Page 7 How to use the unit - Continuation Automatic Stop Function  All models The power light fl ashes and the dryer stops automatically if the unit is used continually for more than 30 seconds. ● To continue using the hand dryer, remove your hands, and then re-insert them.  JT-S2AP only (not applicable to JT-S2A) Heater It alleviates the sensation of cold air.
  • Page 8: Maintenance

    Maintenance Warning Caution Always turn off the ground-fault circuit Wear gloves during maintenance work. ● ● interrupter during maintenance work. Not doing so may result in injuries. Failure to do so may result in an electric shock. Do not allow water to get on the unit. ●...
  • Page 9: Cleaning The Unit Exterior, Hand Drying Area And Air Inlet

    Maintenance - Continuation Cleaning the unit exterior, hand drying area and air inlet Turn the ground-fault circuit interrupter "OFF". Wipe the unit exterior and the hand drying area with a tightly wrung out piece of cloth. When it is unclean, wipe it with a piece of cloth that has ●...
  • Page 10: Trouble Shooting

    Trouble shooting Implement the inspections and procedures below in the following cases. In such cases Inspections Procedures Are any lights in the display on? Turn the ground-fault circuit interrupter "ON". ● Has a blackout occurred? Are you putting your hands in all the way? Place your hands all the way inside the hand drying area.
  • Page 11: Specifications

    Power Input (W) Current (A) Weight (kg) JT-S2AP-W-NE 880 – 980 4.1 – 4.3 250 × 160 × 290(mm) Single-phase JT-S2AP-S-NE 50-60Hz 220 – 240V AC 630 – 730 2.9 – 3.2 ※ ー 250 × 162 × 292(mm) JT-S2A-W-NE ※...
  • Page 12 2006/66/EC Article 20 Information for end-users and Annex II. Français English Votre produit Mitsubishi Electric est conçu et fabriqué avec des matériels et des composants de qualité supérieure qui peuvent être Your MITSUBISHI ELECTRIC product is designed and recyclés et/ou réutilisés.
  • Page 13 Dansk Mitsubishi Electric producten zijn ontwikkeld en gefabriceerd uit eerste kwaliteit materialen. De onderdelen kunnen worden Dit produkt fra MITSUBISHI ELECTRIC er designet og fremstillet gerecycled en/of worden hergebruikt. med kvalitetsmaterialer og komponenter, der kan genindvindes og/ Het symbool betekent dat de elektrische en elektronische eller genbruges.
  • Page 14 Mitsubishi Electric Corporation Head Office: Tokyo Bldg., 2-7-3, Marunouchi, Chiyoda-ku, Tokyo 100-8310, Japan Manufacturer Authorised representative in EU: Mitsubishi Electric Europe B.V.: 1 George Street, Harman House, Uxbridge, Middlesex, UB81QQ Commercial registration no. 33279602 Motor Power Input (kW) 0.67 0.02...
  • Page 15 เอกสารรายการสิ ่ ง ที ่ ต  อ งตรวจสอบ CHECK SHEET FICHE DE CONTRÔLE 检查表 檢視表單 КОНТРОЛЬНЫЙ ЛИСТ Current fuse in control circuit Fusibles à intensité du circuit de commande FUSE1 ..250 V - 20 A ฟ ว ส ก ระแสไฟในวงจรควบคุ ม FUSE2 ..
  • Page 16 Description POWER (LED1) Main cause of error ○ When normal – Tamper prevention 30-second continuous operation (automatic return) Power-supply detection abnormality 2 blinks Power-supply noise (automatic return) Motor abnormality 1 3 blinks Motor: lock/connector detached Motor abnormality 2 4 blinks Motor: brush life limit/brush abnormality Power board temperature abnormality 5 blinks...

This manual is also suitable for:

Jt-s2ap-w-neJt-s2a-w-ne