Common Power Output Problems; Service Information; Specifications - Black & Decker BDI750 Instruction Manual

750w power inverter with usb
Table of Contents

Advertisement

Available languages

Available languages

Common Power Output Problems

Possible Causes
Battery voltage below 10.5 volts
Equipment being operated draws too much power
Inverter in thermal shutdown condition
AC output is shorted

SERVICE INFORMATION

Black & Decker offers a full network of company-owned and authorized service locations. All Black & Decker
Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool
service. Whether you need technical advice, repair, or genuine factory replacement parts, contact the Black &
Decker location nearest you.

SPECIFICATIONS

Maximum Continuous Power:
Surge Capacity:
USB Output:
Input Voltage:
Low Voltage Alarm:
Low Voltage Shutdown:
Thermal Shutdown:
Wave Form:
Fuses:
Input Cables:
Operating Temperature:
Storage Temperature:
Operating/Relative Humidity:
Recommendations
Recharge battery or check DC power supply.
Reduce load to maximum 750 watts.
Allow inverter to cool down. Ensure there is adequate
ventilation around the unit, and the load is no more
than 750 watts for continuous operation.
Unplug the AC appliance. Disconnect the unit from any
12 volt DC power source, then reconnect the unit
BEFORE plugging the appliance back in.
750 Watts
1500 Watts
5 V DC (500mA)
12.8 volts
11.0 ± 0.3 volts DC
10.5 ± 0.3 volts DC
Automatic
Modified Sine Wave (MSW)
Internal: 30 Amps X3
Battery clip cables
10-20°C (50-68°F)
0-40°C (32-104°F)
5-95% non-condensing
24