Electrical Control Function
Compressor
4 way valve
Outdoor fan
Indoor fan
For the others type::
The compressor is running, and 4-way valve and outdoor fan stop. The indoor fan works as anti-cold wind
procedure. When defrosting is over, the compressor keeps running and the 4-way valve and outdoor fan will
start up.
For 3-phase outdoor units:
Condition of defrosting:
l
T3<0℃ and the compressor keeps running over 45 minutes. Meanwhile T3<-3℃ for 3minutes.
Condition of ending defrosting:
l
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to normal
heating mode.
A: T3 rises to be higher than 20℃.
B: The machine has run for 10 minutes in defrosting.
Defrosting action:
l
The compressor is running, and 4-way valve and outdoor fan stop. The indoor fan works as anti-cold wind
procedure. When defrosting is over, the compressor keeps running and the 4-way valve and outdoor fan will
start up.
Setting defrosting time
45S
40S
10S
45S
40S