Bull Escala EPC400 Connecting Manual page 52

Bull escala epc series rack-mountable servers connecting guide
Hide thumbs Also See for Escala EPC400:
Table of Contents

Advertisement

3. Only if Powerconsole is used
Establish the connection between the workstation and CS/2600 on the serial port J0
– using the cu command on the PowerConsole side (see step 1).
4. Switch the CS/2600 to monitor mode:
– make a hardware reset (button on the left side of the CS/2600) as described in the
CS/2600 Installation Guide.
5. Wait few seconds, then press <Enter> two–three times during regular interval of 1
second, the following prompt must be displayed:
3Com Corporation CS/2600 Series Monitor
6. Make a copy of the original floppy diskette to a new diskette
– as described in the CS/2600 Installation Guide. (for this, use the command "co")
7. Take away the original diskette and use the new one.
8. Key in the command (after >):
The following menu will be displayed:
9. Choose the menu Change parameters, by keying:
10.Modify the following parameters as:
5.
6.
A.
B.
Refer to the CS/2600 Installation Guide to see how to modify these values.
11. IP/TFTP parameters Configuration
Select the menu B that appears once TFTP Boot protocol has been selected for menu A:
– setup the "Adr discover protocol" with Local Information
– setup the "Client Ip address" with the Ethernet address chosen for the CS2600 server
(@IPCS/2600): for example 120.184.33.10
– setup the "Gateway address" with for example 120.184.33.10, if necessary
(customer's LAN)
– setup the "Subnet mask value" with the subnet mask of the client LAN network,
for example: 255.255.255.0
12.Exit from all the menus with <Esc> till the prompt >
13.Reset the CS/2600 server softly.
– (Push the reset switch in the front panel).
14.At the end of self testing phase
(Self test and boot state leds go off),
– Wait at least 2 minutes (the led of the floppy driver turns off),
6-22
EPC Connecting Guide
>
> fc <Enter>
Firmware Configuration Utility Commands:
C
– Change parameters
D
– Display parameters
Esc
– Exit to monitor
C <Enter>
Monitor
Initial Boot source
Boot protocol
IP/TFTP parameters
Disabled
Local Floppy
TFTP Boot