Failures Occurring When The Ring Protocol Functionality Is Used - Alaxala AX6700S Troubleshooting Manual

Hide thumbs Also See for AX6700S:
Table of Contents

Advertisement

3 Troubleshooting Functional Failures During Operation

3.5.3 Failures occurring when the Ring Protocol functionality is used

This subsection describes failures occurring in the Autonomous Extensible Ring Protocol.
The Autonomous Extensible Ring Protocol (abbreviated hereafter to Ring Protocol) is a
Layer 2 network redundancy protocol for ring topologies.
If communication is not possible when the Ring Protocol is used, use the following analysis
flowchart to determine the problem and isolate the cause.
Figure 3-3 Analysis flowchart
If operation cannot be performed correctly or a ring network failure is detected when the
Ring Protocol is used, use the failure analysis method described in the table below to
isolate the cause of the problem for all nodes in the target ring network.
Table 3-15 Failure analysis method for the Ring Protocol
No.
Items to check and
commands
1
Use the
show axrp
to check the operating status of
the Ring Protocol.
56
Action
command
If
enable
If a hyphen (-) is displayed for
the Ring Protocol have not been configured. Check the
configuration.
If
disable
disabled. Check the configuration.
If
Not Operating
functionality is not running. Check the configuration for any conflict
(for example, an incorrect combination of the attribute and ring port
for the operating mode of the Switch). If there is no conflict in the
configuration, for AX6700S, AX6600S, or AX6300S series switches,
go to No. 2. For AX3800S, AX3600S, or AX2400S series switches,
go to No. 3.
is displayed for
State, go to No. 3.
Oper
Oper
is displayed for
State, the Ring Protocol is
Oper
is displayed for
State, required items for using
State, the Ring Protocol
Oper