Overview Of Analyzing Failures Of All Or Part Of The Switch; Failure Analysis For Ax6700S, Ax6600S, And Ax6300S Series Switches - Alaxala AX6700S Troubleshooting Manual

Hide thumbs Also See for AX6700S:
Table of Contents

Advertisement

1.2 Overview of analyzing failures of all or part of the Switch

1.2.1 Failure analysis for AX6700S, AX6600S, and AX6300S series switches

If a failure occurs during operation and the actual switch can be looked at, take appropriate
action as described in 2.1 Troubleshooting faults for AX6700S, AX6600S, and AX6300S
series switches to troubleshoot the failure.
The status of a switch is shown in the basic control unit (BCU) for AX6700S series switches,
in the control and switching unit (CSU) for AX6600S series switches, and in the
management and switching unit (MSU) for AX6300S series switches. Table 1-1 LED
indications, buttons, and connectors describes the LED indications of the BCU, CSU, and
MSU and what they mean. Figure 1-1 Example layout of the front panel shows a front panel
layout example.
For LED indications of optional modules other than the BCU, CSU, and MSU, such as the
BSU, a NIF, a power supply unit, or a fan unit module, see the Hardware Instruction Manual.
The manual also provides front panel layouts other than the one shown in Figure
1-1 Example layout of the front panel.
Note that even when you cannot look at the actual switch, you can still check the LED
indications of the switch and troubleshoot failures accordingly, just like when you can look
at the actual switch, by issuing operation commands from a remote terminal.
Table 1-1 LED indications, buttons, and connectors
No.
Name
1
STATUS
2
SYSTEM
OPERATIO
N PANEL
3
ACC
4
SD CARD
5
RESET
6
ACH
Type
Status
LED: Green,
Operating status of
orange, or red
BCU, CSU, or MSU
LCD and
System operation
operation keys
panel
LED: Green
Memory card status
Connector
SD card slot
Button
Manual reset button
for the device
(non-locking)
Button for altering the
Button
active and standby
(non-locking)
BCU, CSU, or MSU
modules
Description
Green: The switch is available for operation.
Orange: The unit is under self diagnosis
operation.
Blinking green: The unit is loading software.
Red: A fault has been detected.
Off: The power is off. (The BCU, CSU, or
#1
MSU can be replaced.)
The system operation panel displays device
information, operating instructions, or failure
information. (For details, see the
Configuration Guide.)
Green: The memory card is being accessed.
Do not remove the memory card.
Off: The memory card is idle. The memory
card can be inserted or removed.
SD card slot
Pressing the button for one second: Perform
this operation if, for example, a fault occurs
#2#3
with the switch.
Pressing the button for five seconds:
Perform this operation if the password is
#2#4
forgotten.
When the BCU, CSU, or MSU modules are
duplicated, pressing the button swaps the
active and standby units.
1 Overview
#2#5
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax6300sAx2400sAx6600sAx3800sAx3600s

Table of Contents