10-3. Indoor Unit
10-3-1. Installation Location
• A place which provides enough spaces around
the indoor unit as shown in the diagram.
• A place where there are no obstacles near the air
inlet and outlet.
• A place which allows easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be
opened.
CAUTION
• The indoor unit shall be installed so that the
top of the indoor unit is positioned at least 2m
in height.
Also, avoid putting anything on the top of the
indoor unit.
• Direct sunlight on the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f sources.
(For details, see the owner's manual.)
Remote controller
• Should be placed where there are no obstacles,
such as curtains, that may block the signal.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m away from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
(Side view)
(Top view)
Reception
Remote
range
controller
*: Axial distance
Fig. 10-3-1
Indoor unit
Reception
range
Remote controller
10-3-2. Drilling and Mounting Installation
Plate
Drilling
When install the refrigerant pipes from the rear.
1. Decide the installation plate mounting position
on the wall.
2. Mark the corresponding pipe hole wall positions
according to the positioning marks (
installation plate.
3. Drill the pipe holes (Ø65 mm) slightly slanted
downward to the outside.
NOTE :
• When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the installation plate
Pipe hole
Indoor unit
6 Mounting screw
– 67 –
The center of the
pipe hole
Pipe
hole
Fig. 10-3-2
ð
Anchor bolt holes
Pipe hole
1 Installation plate
Fig. 10-3-3
) on the