Toshiba RAS-4M23SAV-E Service Manual page 35

Split type
Hide thumbs Also See for RAS-4M23SAV-E:
Table of Contents

Advertisement

Outdoor Unit : RAS-4M23SACV-E
<Cooling>
Temperature
No. of
condition
operating
units
Indoor
Outdoor
1 unit
2 units
3 units
27 /19°C
35 / –°C
4 units
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 meters × 4 units (5m/each indoor unit)
Operating combination
Standard
(Unit)
pressure
P (MPa)
A
B
C
D
10
0.8 to 1.0
13
0.7 to 0.9
16
0.6 to 0.8
10
10
0.8 to 1.0
13
10
0.8 to 1.0
16
10
0.8 to 1.0
13
13
0.8 to 1.0
16
13
0.7 to 0.9
10
10
10
0.8 to 1.0
13
10
10
0.8 to 1.0
16
10
10
0.8 to 1.0
13
13
10
0.8 to 1.0
16
13
10
0.8 to 1.0
13
13
13
0.8 to 1.0
16
13
13
0.8 to 1.0
10
10
10
10
0.9 to 1.1
13
10
10
10
0.9 to 1.1
16
10
10
10
0.9 to 1.1
13
13
10
10
0.9 to 1.1
– 35 –
Heat exchanger
Indoor
pipe temp.
fan
(Manual)
T1 (°C)
T2 (°C)
13 to 15
45 to 47
High
8 to 10
46 to 48
High
8 to 10
52 to 54
High
11 to 13
58 to 60
High
11 to 13
58 to 60
High
11 to 13
58 to 60
High
11 to 13
58 to 60
High
11 to 13
58 to 60
High
13 to 15
56 to 58
High
13 to 15
56 to 58
High
13 to 15
56 to 58
High
13 to 15
56 to 58
High
13 to 15
56 to 58
High
13 to 15
56 to 58
High
13 to 15
56 to 58
High
15 to 17
50 to 52
High
15 to 17
50 to 52
High
15 to 17
50 to 52
High
15 to 17
50 to 52
High
Compressor
Outdoor
revolution
fan
(rps)
MED
29
MED
48
MED
69
MED
61
MED
61
MED
65
MED
65
MED
65
MED
66
MED
66
MED
68
MED
68
MED
68
MED
68
MED
68
MED
71
MED
71
MED
71
MED
71