Description Of Fault Codes For Eoc Iii; Fault Code Chart - Jenn-Air JDS8850BD Service Manual

Dual fuel slide-in range
Hide thumbs Also See for JDS8850BD:
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.

Description of Fault Codes for EOC III

Each fault code consists of 4 digits and is structured as follows:
st
1
(Leftmost) Digit:
Primary Failure System
1 – Local to Control System
3 – Sensor or Meat Probe
4 – Input to Control System
9 – Door Lock
If a fault is detected, then one of the following three messages will be scrolled on the display:
FAULT DETECTED PRESS ENTER TO TRY AGAIN. This message displays when a fault is detected while a
cooking function is active. Clear by pressing the Cancel keypad.
FEATURE NOT AVAILABLE. This message displays when a fault is detected while entering data during initial
programming and also when a locked out function is detected. Clear by pressing any key.
FAULT DETECTED DISABLE POWER TO CLEAR. This message displays when a runaway temperature condition
is detected while the control is in idle mode. Press any key to clear the message, but the fault remains until the
control senses a Power-On reset.

FAULT CODE CHART

Fault
Description
Code
1c1c
Shorted key.
1c2c
Membrane keyboard disconnected.
1c4c
Board – to – Board communication failure.
1c6c
EEPROM hardware fault.
1c7c
Control not calibrated.
1c8c
EEPROM CRC error – User Options.
1c81
EEPROM CRC error – Cook Profile.
1d11
Unlocked runaway temperature – 600° F
1d21
Locked runaway temperature – 950° F
3d11
Temperature sensor open.
3d21
Temperature sensor shorted.
3d41
Meat probe shorted.
3d51
Meat probe not calibrated.
4d11
Door switch not closed when locked.
4d21
No cooling fan rotation.
4d31
Cooling fan on when de-energized.
4d41
Cooling fan overspeed.
4d51
Door switch circuit fault.
9d11
Latch will not lock.
9d21
Latch will not unlock.
9d31
Latch both locked and unlocked.
24
!
WARNING
nd
2
Digit: Alpha-Character
d – Diagnostic Failure (measurable)
c – Control-Related Error (not measurable)
Ensure ribbon cable is securely connected, inspect ribbon cable and
connector (shorts, breakage, corrosion, etc.). If OK, replace control.
Ensure ribbon cable is securely connected, inspect ribbon cable and
connector (shorts, breakage, corrosion, etc.). If OK, replace control.
Replace control.
Replace control.
Replace control.
Replace control.
Replace control.
Ohm sensor and harness (see "Oven Sensor" chart). If OK, change
control.
Ohm sensor and harness (see "Oven Sensor" chart). If OK, change
control.
Check connections, sensor (see "Oven Sensor" chart) and harness. If
OK, replace control.
Check connections, sensor (see "Oven Sensor" chart) and harness. If
OK, replace control.
Check probe jack and harness. If OK, check meat probe (see "Meat
Probe" chart).
Check probe jack and harness. If OK, check meat probe (see "Meat
Probe" chart).
Check connections, switch, harness, and motor. If OK, replace control.
Check cooling fan motor and harness. If OK, replace control.
Check cooling fan motor and harness. If OK, replace control.
Check cooling fan motor and harness. If OK, replace control.
Check connections, harness, and motor. If OK, replace control.
Check wire connections. If OK, replace motorized door lock.
Check wire connections. If OK, replace motorized door lock.
Check wire connections. If OK, replace motorized door lock.
rd
3
Digit: Secondary
Failure Mechanism
Component to Troubleshoot/Replace
16026929
th
4
Digit : Oven
Cavity Number
1 – Upper (Single) Oven
2 – Lower Oven
c – Control System
© 2006 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jds9860bdJds9865bd

Table of Contents