Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Electronic Oven Control (EOC) III Testing Procedures
ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature
Oven Temperature Adjustment
Determines oven cavity offset
temperature (range from -35° F to
+35° F, or -21° C to +21° C).
Time Options
Determines control time, day of
week, 12/24 hour clock.
Time Set
Determines time of day (Monday
thru Sunday) to display on control.
Day of Week
Determines day of week (Monday
thru Sunday) to display on control
12/24-Hour Clock Display
Determines 12-hour or 24-hour
clock display on control.
Clock & Day Display Disable
Determines if time of day and day
of week will display on control.
Language Display
Determines language display on
control (English, French, or
Spanish).
C/F (Celsius/Fahrenheit) Display
Determines temperature display
on control (C or F).
Auto Convection
When enabled, reduces the
Convection Bake and Pastry
temperatures by 25° F (-3.9° C).
Sabbath Mode
Bases on the Jewish guidelines for
Sabbath/Holiday requirements.
Tone Options
Determines cook tones, timer tones
and volume settings.
12-Hour Shutoff
Disables 12-hour shutoff, allowing
the oven to operate indefinitely.
20
!
WARNING
Warm
Drawer
ATM PADS
Access Procedure
Press the Setup pad, then press the right ATM
pad until TEMP ADJUST displays. Press the left
ATM pad to select oven TEMP ADJUSTMENT
settings.
Press the Setup pad, then the left ATM pad to
select TIME OPTIONS.
Press the Setup pad, then the left ATM pad, then
the left ATM pad again to set the time of day
clock.
Press the Setup pad, then the left ATM pad, then
press the right ATM pad until DAY displays. Press
the left ATM pad to select the day.
Press the Setup pad, then the left ATM pad, then
press the right ATM pad until 12/24HR displays.
Press the left ATM pad to select 12/24 HR clock.
Press the Setup pad, then press the right ATM
pad until DISABLE displays. Press the left ATM
pad to select DISABLE settings.
Press the Setup pad, then press the right ATM
pad until LANGUAGE displays. Press the left
ATM pad to select LANGUAGE settings.
Press the Setup pad, then press the right ATM
pad until C/F displays. Press the left ATM pad to
select C/F settings.
Press the Setup pad, then press the right ATM
pad until AUTO CONVECT displays. Press the
left ATM pad to select AUTO CONVECT settings.
Press the Setup pad, then press the right ATM
pad until SABBATH displays. Press the left ATM
pad to select SABBATH settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM pad
to select TONES options.
Press the Setup pad, then press the right ATM
pad until 12HR Shutoff displays. Press the left
ATM pad to select 12-HOUR SHUTOFF settings.
16026929
Modification Procedure
Enter the offset temperature setting desired
using the digits pads. Press the right ATM
pad for + temperature adjustment, or the
left ATM pad for – temperature adjustment.
Press 0 to reset control back to no
temperature adjustment. Wait 3 seconds
for the control to accept the request. Press
Setup to exit.
Press the right ATM pad to scroll to the
desired function to modify.
Enter the correct time using the digits pads
and press Enter. Press the left ATM pad
to select AM or the right ATM pad to select
PM. Press Setup to exit.
Press the right ATM pad until the correct
day displays, then press the left ATM pad
to select. Press Setup to exit.
Press the left ATM pad to select 12-hour
clock, or the right ATM pad to select 24-
hour clock. Press Setup to exit.
Press the left ATM pad to select TIME, or
the right ATM pad to scroll to DAY, then
press the left ATM pad. Press the left ATM
pad to turn display on or the right ATM pad
to turn display off. Press Setup to exit.
Press the right ATM pad until the correct
language displays (English, French or
Spanish), then press the left ATM pad.
Press Setup to exit.
Press the left ATM pad to select Celsius or
the right ATM pad to select Fahrenheit.
Press Setup to exit.
Press the left ATM pad to turn on auto
convect, or the right ATM pad to turn off
auto convect. Press Setup to exit.
Press the left ATM pad to select Manual
Sabbath mode, or the right ATM pad to
select Auto Sabbath mode. Press the left
ATM pad to turn on Sabbath mode, or the
right ATM pad to turn off Sabbath mode.
Press Setup to exit.
Press the right ATM pad to scroll to the
desired tone to modify.
Press the left ATM pad to turn on 12-hour
shutoff, or the right ATM pad to turn off 12-
hour shutoff. Press Setup to exit.