Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Feature
208/240 V Setting
Determines range operating
voltage (208 or 240 VDC).
Cook Tones
Determines the number and
duration of cook time reminder
chimes.
Timers Tones
Determines the number and
duration of timer reminder
chimes.
Volume
Determines volumes of cook
and timer tones.
Energy Saver Mode
Enables a 1 watt standby
feature. If no pad is pressed
within 5 minutes, the control
enters a sleep mode.
Demo Mode
Enables a 1 watt standby
feature. If no pad is pressed
within 5 minutes, the control
enters into a sleep mode.
Service Mode
Enables access to service
menus.
Test Access
Enables access to service
menus.
Faults Access
Displays the 10 most recent
faults produced by the
controller.
Software Versions Access
Displays the software and
EEPROM revision levels.
Display Test
Illuminates all lamps on the
control.
Control Lockout
Disables the keypad control
and locks the oven cavity door.
© 2006 Maytag Services
!
WARNING
Access Procedure
Press the Setup pad, then press the right
ATM pad until 208/240 displays. Press the
left ATM pad to select 208/240 V settings.
Press the Setup pad, then press the right
ATM pad until TONES displays. Press the
left ATM pad. Press the left ATM pad again
to select COOK TONES settings.
Press the Setup pad, then press the right
ATM pad until TONES displays. Press the
left ATM pad. Press the right ATM pad to
scroll to TIMERS TONES. Press the left ATM
pad to select TIMERS TONES settings.
Press the Setup pad, then press the right
ATM pad until TONES displays. Press the
left ATM pad to select VOLUME settings.
Press the Setup pad, then press the right
ATM pad until ENERGY SAVER displays.
Press the left ATM pad to select ENERGY
SAVER mode settings.
Press the Setup pad, then press the right
ATM pad until DEMO displays. Press the left
ATM pad to select DEMO mode settings.
Press the Setup pad, then press the right
ATM pad until SERVICE displays. Press the
left ATM pad to select SERVICE menu
options.
Press the Setup pad, then press the right
ATM pad until SERVICE displays. Press the
left ATM pad to select SERVICE menu
options.
Press the Setup pad, then press the right
ATM pad until SERVICE displays. Press the
left ATM pad to select SERVICE menu
options.
Press the Setup pad, then press the right
ATM pad until SERVICE displays. Press the
left ATM pad to select SERVICE menu
options.
Press the Setup pad, then press the right
ATM pad until SERVICE displays. Press the
left ATM pad to select SERVICE menu
options.
Press the Back and Setup pads
simultaneously for 5 seconds to lock.
16026929
Modification Procedure
Press the left ATM pad to select 208 VDC, or the
right ATM pad to select 240 VDC. Press Setup to
exit.
Press the left ATM pad to select 1 – 30 (1 chime
every 30 seconds after the initial 4 chimes), or
press the right ATM pad to scroll to 1 – 60 (1 chime
every 60 seconds after the initial 4 chimes) or 1
BEEP (no additional chimes after the initial 4
chimes). Press the left ATM pad to select the
desired setting. Press Setup to exit.
Press the left ATM pad to select 2 – 30, or 2
chimes every 30 seconds for up to 5 minutes (after
the initial chime), or press the right ATM pad to
scroll to 2 – 60, or 2 chimes every 60 seconds for
up to 30 minutes (after the initial chime), or 1 BEEP
(no additional chimes after the initial chime). Press
the left ATM pad to select the desired setting.
Press Setup to exit.
Press the right ATM pad until VOLUME displays.
Press the left ATM pad. Press the left ATM pad to
select HIGH, or the right ATM pad to scroll to
MEDIUM or LOW. Press the left ATM pad to select
desired setting. Press Setup to exit.
Press the left ATM pad to enter the energy saver
mode or the right ATM pad to exit the energy saver
mode. Press Setup to exit.
Press the left ATM pad to enable the DEMO mode
or the right ATM pad to exit the DEMO mode.
Once the DEMO mode begins, press any key to
exit. Press Setup to exit, also.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to TEST menu. Press
the left ATM pad to select TEST options. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to the FAULTS menu.
Press the left ATM pad to select FAULTS options.
Press Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to the VERSIONS
menu. Press the left ATM pad to view. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to DISPLAY TEST.
Press the left ATM pad. Press Setup to exit.
Press the Back and Setup pads simultaneously for
5 seconds to unlock.
21