MUND CLIMA MUP-09-WF Owner's Manual

Fan coil unit wall mounted type

Advertisement

Fan Coil Unit

Wall Mounted Type

OWNER'S MANUAL
Thank you for choosing our air conditioners. P lease read this owner's
manual carefully before operation and keep it for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUP-09-WF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MUND CLIMA MUP-09-WF

  • Page 1: Wall Mounted Type

    Fan Coil Unit Wall Mounted Type OWNER'S MANUAL Thank you for choosing our air conditioners. P lease read this owner's manual carefully before operation and keep it for future reference.
  • Page 2 MUP-09-WF MUP-12-WF MUP-18-WF...
  • Page 3: Table Of Contents

    CONTENTS Operation and maintenance ■Notices for operation···············································································1 ■Notices for use························································································3 ■Specifications························································································· · ■Name and function of each part····························································· · ■Operation of wireless remote control····················································· ·· ■Wired controller operation········ ····························································11 ■Emergency operation············································································18 ■Clean and care······················································································19 ■Troubleshooting·····················································································21 Installation service ■Notices for installation·········································································· ·...
  • Page 4: Notices For Operation

    Notices for operation Earth: The ground Be sure to pull out the power Select the most appropriate tem- plug when not using the air co- be connected! perature. nditioner for a long time. Keep room cool- er than outside about 5 degree. If not, please ask the qualified person- nel to install.
  • Page 5 The airflow direction can be adjusted appro- If the supply cord is damaged, it must be replaced priately. At operating, adjust the vertical airflow by the manufacturer or its service agent or a direction by adjusting the louvers of upward/do- similarly qualified person in order to avoid a wnward direction.
  • Page 6: Notices For Use

    Notices for use Working principle for cooling Principle: The unit absorbs energy from the air indoors and takes the energy away through circulation of cooling water, so as to reduce indoor ambient temperature. Accordingly, the cooler the water, the larger the cooling capacity.
  • Page 7: Specifications

    Specification MUP-09-WF MUP-12-WF MUP-18-WF 220 V-2240V 50 Hz ≤1.5MPa ≤1.5MPa...
  • Page 8: Name And Function Of Each Part

    Name and function of each part The unit Air in Air out The pattern in displayer Cool Wireless Power cable remote control Heat Remote control Front panel Set temp. Filter Guide louver Wall pipe Bind tape Drain pipe...
  • Page 9 Functions of wireless remote control Note: Be sure that there are no obstructions between receiver and remote control; Do not drop or throw the remote control; Don't let any liquid drop into the remote control or leave the remote control under the sunlight or place where is very hot. SLEEP Signal transmitter SLEEP button...
  • Page 10: Operation Of Wireless Remote Control

    Operation of wireless remote control Functions of wireless remote control Notice: This is a general remote control, it could be used for multiple types (functions) of air conditioners. For some models without the functions specified here, we preserve the right to not to inform exclusively.
  • Page 11 Cunctions of wireless remote control Notice: This is a general remote control, it could be used for multiple types (functions) of air condictioners. For some models without the funcions specified here, we prese- rve the right to not to inform exclusively. TIMER ON TIMER ON BUTTON Press the TIMER ON button to...
  • Page 12 Operation of wireless remote control Guide for operation — General operation 1. Press SLEEP button to set the sleep state. 2. Press TIMER ON and TIMER OFF button to schedule the unit ON/OFF. 3. Press LIGHT button to control the on and off of the indicator board.
  • Page 13 Operation of wireless remote control Press +and - buttons simultaneously to lock or unlock the wireless remote control. If it is locked, the mark will display; when pressing any button, the mark will blink for three times but the air condictioner has no respondence. If unlocked, the mark will disappear. Switch between Fahrenheit and Centigrade.
  • Page 14 (optional) TIMER -11-...
  • Page 15 -12-...
  • Page 16 TIMER -13-...
  • Page 17 TIMER TIMER -14-...
  • Page 18 TIMER parameters display interface. TIMER TIMER -15-...
  • Page 19 TIMER TIMER -16-...
  • Page 20 -17-...
  • Page 21: Emergency Operation

    Emergency operation Indicator light control of the displayer When sleeping at night, the user can get the indicator light off. Get the displayer indicator light on: When setting the light function,the mark will display on the remote controller screen by pressing this button.
  • Page 22 Clean and care Caution Turn power off and pull out the power plug before cleaning air conditioner, or it may cause shock. Never sprinkle water on the unit for cleaning because it can cause electric shock. Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.) Clean the front panel When cleaning the front panel, please dip the cloth into the water temperature of 45...
  • Page 23: Clean And Care

    Clean and care Check before use 1. Be sure that nothing obstructs the air outlet and intake vents. 2. Check that whether ground wire is properly connected or not. 3. Check that whether the batteries of air conditioner are changer or not.
  • Page 24: Troubleshooting

    Troubleshooting CAUTION Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Troubleshooting Not operate immediately when the air Once the air conditioner is stopped, it will conditioner is restarted.
  • Page 25 Troubleshooting Phenomenon Troubleshooting Has the power been shut down? The unit can not run Is power plug loosed? Is the circuit protection device tripped off or not? Is voltage higher or lower? (Tested by professionals) Is the TIMER correctly used? Is Temp.
  • Page 26 Troubleshooting Phenomenon Troubleshooting The unit cannot deliver air In HEAT mode, when the temperature of the heat exchanger is very low, that air in order to prevent cool In COOL mode, when the temperature of the heat exchanger is very high, that will stop deliver air in order to prevent hot air.
  • Page 27 Notices for installation Important Notices The unit installation work must be done by qualified personnel according to the local rules and this manual. Before installating, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved, due to discommodious contacts.
  • Page 28: Notices For Installation

    Notices for installation Safety Requirements For Electric Appliances 1. The power supply be used the rated voltage and AC exclusive circuit, the power cable diameter should be satisfied. 2. Don't drag the power cable emphatically. 3. It should be reliably earthed, and it should be connected to the special earth device, the installation work should be operated by the professional.
  • Page 29 The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures. -26-...
  • Page 30: Install The Unit

    Install the unit Install the rear panel 1.Always mount the rear panel horizontally. Due to the water tray of the unit has been adopted the both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and level should be 0 or more, that is good for condensing water drainage.
  • Page 31 Install the unit NOTE: When connecting the electric wire if the wire length is not enough, please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed. The electric wiring must be correctly connected, wrong connection may cause spare parts malfunction.
  • Page 32 External water pipe connection sketch -29-...
  • Page 33: Check After Installation And Test Operation

    Check after installation and test operation Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling(heating) Have you done the water leakage test? capacity It may cause condensation and dripping.
  • Page 34: Installation Instructions

    Installation Instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter downwards to remove it. (See Fig.a) Fig. a Fig. b 2. Mount the healthy filter onto the air filter,(as Air filter shown in Fig.b).