Grandstream Networks HandyTone-486 User Manual

Grandstream Networks HandyTone-486 User Manual

Analog telephone adaptor for firmware version 1.0.8.16
Hide thumbs Also See for HandyTone-486:

Advertisement

Quick Links

User Manual

HandyTone-486
Analog Telephone Adaptor
For Firmware Version 1.0.8.16

Advertisement

Table of Contents
loading

Summary of Contents for Grandstream Networks HandyTone-486

  • Page 1: User Manual

    User Manual HandyTone-486 Analog Telephone Adaptor For Firmware Version 1.0.8.16...
  • Page 2: Table Of Contents

    Access the Web Configuration Menu..............15 6.2.2 End User Configuration ..................16 6.2.3 Advanced User Configuration ................20 6.2.4 Saving the Configuration Changes..............30 6.2.5 Rebooting the HandyTone-486 from remote ............. 30 ............31 ONFIGURATION THROUGH A ENTRAL ERVER SOFTWARE UPGRADE ..................... 32...
  • Page 3 HandyTone-486 User Manual Grandstream Networks, Inc. TFTP/HTTP............32 IRMWARE PGRADE THROUGH ................33 ONFIGURATION OWNLOAD ........33 IRMWARE AND ONFIGURATION REFIX AND OSTFIX ......33 ANAGING IRMWARE AND ONFIGURATION OWNLOAD RESTORE FACTORY DEFAULT SETTING............34 GLOSSARY OF TERMS..................... 35...
  • Page 4: Welcome

    HandyTone-486 User Manual Grandstream Networks, Inc. Welcome Congratulations on becoming an owner of HandyTone-486. You made an excellent choice and we hope you will enjoy all its capabilities. Grandstream's award-wining HandyTone-486 is an all-in-one VoIP integrated access device that features superb audio quality, rich functionalities, high level of integration, compactness and ultra- affordability.
  • Page 5: Installation

    HandyTone-486 User Manual Grandstream Networks, Inc. Installation HandyTone-486 Analog Telephone Adaptor is an all-in-one VoIP integrated device designed to be a total solution for networks providing VoIP services. The HandyTone-486 VoIP functionalities are available via a regular analog telephone. The following photo illustrates the appearance of a HandyTone-486.
  • Page 6: What Is Included In The Package

    3) One Ethernet cable Safety Compliances The HandyTone-486 is compliant with various safety standards including FCC/CE and C-tick. Its power adaptor is compliant with UL standard. The HandyTone-486 should only operate with the universal power adaptor provided in the package. Warranty Grandstream has a reseller agreement with our reseller customer.
  • Page 7: Product Overview

    HandyTone-486 User Manual Grandstream Networks, Inc. Product Overview Key Features • Supports SIP 2.0(RFC 3261), TCP/UDP/IP, RTP/RTCP, HTTP, ICMP, ARP/RARP, DNS, DHCP (both client and server), NTP, PPPoE, STUN, TFTP, etc. • Built-in router, NAT, Gateway and DMZ port forwarding. Can also be configured to function as a two Ethernet ports bridge (NAT function is disabled) •...
  • Page 8: Hardware Specification

    Rev.2.0 is that a HandyTone-486 Rev.2.0 line port can function as PSTN pass through while a HandyTone-486 (Rev.1.0, old model, no longer shipped) line port is just a life line port and will bridge to PSTN only when the device is out of power.
  • Page 9: Basic Operations

    HandyTone-486 stores a voice prompt menu (Interactive Voice Response or IVR) for quick browsing and simple configuration. To enter this voice prompt menu, simply press the button on the HandyTone-486 or pick up the phone and dial “***”. The following table shows how to use the voice prompt menu to configure the device.
  • Page 10: Make Phone Calls

    HandyTone-486 User Manual Grandstream Networks, Inc. • Once the LED button is pressed, it enters voice prompt main menu. If the button is pressed again while it is already in the voice prompt menu state, it jumps to “Direct IP Calling” option and dial tone plays in this state •...
  • Page 11: Call Hold

    HandyTone-486 User Manual Grandstream Networks, Inc. a dial tone. Enter a 12-digit target IP address to make a call. Destination ports can be specified by using “*4” (encoding for “:”) followed by the port number. Examples: If the target IP address is 192.168.0.10, the dialing convention is Voice Prompt with option 47, then 192 168 000 010 followed by pressing the “#”...
  • Page 12: 5.2.5.2 Attended Transfer

    5.2.6 3-way Conferencing HandyTone-486 rev. 2.0 supports 3-way conference. Assume that call party A and B are in conversation. A wants to bring C in the conference: 1. A press “FLASH” button on the analog phone to get a dial tone.
  • Page 13: Call Features

    To make a PSTN call, press the PSTN access code (*00 by default, or any number configured in web configuration page) to switch to PSTN line and get a dial tone, then dial the PSTN number. When HandyTone-486 is out of power, it will function as a jack. User can use the same analog phone for PSTN calls.
  • Page 14: Fax

    HandyTone-486 supports FAX in two modes: T.38 (Fax over IP) and fax pass through. T.38 is the preferred method because it is more reliable and works well in most network conditions. If the service provider supports T.38, please use this method by selecting Fax mode to be T.38.
  • Page 15: Configuration Guide

    6.1.2 STATIC IP Mode Follow section 5.1 with voice menu option 01 to enable HandyTone-486 to use STATIC IP mode, then use option 02, 03, 04, 05 to set up IP address, Subnet Mask, Gateway, and DNS server respectively. 6.1.3 TFTP Server Address Follow section 5.1 with voice menu option 06 to configure the IP address of the TFTP server.
  • Page 16: End User Configuration

    “0”s as the browser will parse in octet. e.g.: if the IP address is: 192.168.001.014, please type in: 192.168.1.14. 6.2.2 End User Configuration Once this request is entered and sent from a Web browser, the HandyTone-486 will respond with the following login screen: Grandstream Device Configuration Password Login All Rights Reserved Grandstream Networks, Inc.
  • Page 17 HandyTone-486 User Manual Grandstream Networks, Inc. STATUS BASIC SETTINGS ADVANCED SETTINGS End User Password: (purposely not displayed for security protection) IP Address: dynamically assigned via DHCP (default) or PPPoE (will attempt PPPoE if DHCP fails and following is non- blank)
  • Page 18 If set to “Yes”, then the displayed time will be 1 hour ahead of normal time. Default is No. Device Mode Default is NAT router mode. HandyTone-486 Rev.2.0 can be configured in Bridge mode so the device functions as a bridge. Cloned WAN MAC Allow user to set a specific MAC address.
  • Page 19 DMZ IP: Forward all WAN IP traffic to a specific IP address if no matching port is used by HandyTone-486 itself or in the defined port forwarding. Port Forwarding: Allow user to forward a matching (TCP/UDP) port to a specific LAN IP address with a specific (TCP/UDP) port.
  • Page 20: Advanced User Configuration

    HandyTone-486 User Manual Grandstream Networks, Inc. MAC Address The device ID, in HEX format. This is very important ID for ISP troubleshooting. This field shows WAN port IP address. WAN IP Address Product Model This field contains the product model info, such as HT486 Rev:2.0 Program: This is the main software release.
  • Page 21 HandyTone-486 User Manual Grandstream Networks, Inc. STATUS BASIC SETTINGS ADVANCED SETTINGS Admin Password: (purposely not displayed for security protection) sip.mycompany.com SIP Server: (e.g., sip.mycompany.com, or IP address) Outbound Proxy: (e.g., proxy.myprovider.com, or IP address, if any) 3123763006 SIP User ID:...
  • Page 22 HandyTone-486 User Manual Grandstream Networks, Inc. Use DNS SRV: User ID is phone number: SIP Registration: Unregister On Reboot: 3600 Register Expiration: (in seconds. default 1 hour, max 45 days) Early Dial: Yes (use "Yes" only if proxy supports 484 response)
  • Page 23 HandyTone-486 User Manual Grandstream Networks, Inc. FXS Impedance: 600 Ohm (North America) Caller ID Scheme: Bellcore (North America) Onhook Voltage: Polarity Reversal: Yes (reverse polarity upon call establishment and termination) time.nist.gov NTP Server: (URI or IP address) Send Anonymous: Yes (caller ID will be blocked if set to Yes)
  • Page 24 Override MTU Size: Update Cancel Reboot All Rights Reserved Grandstream Networks, Inc. 2005 Admin Password Administrator password. Only administrator can configure the “Advanced Settings” page. Password field is purposely left blank for security reason after user clicks UPDATE button. This field is case sensitive and the maximum password length is 25 characters.
  • Page 25 HandyTone-486 User Manual Grandstream Networks, Inc. Preferred Vocoder The HandyTone ATA supports 6 different codec types including G.711 A/U law,G.723.1, G.726, G.729A/B, iLBC. A user can configure Codecs in a preference list that will be included with the same preference order in SDP message.
  • Page 26 HandyTone-486 User Manual Grandstream Networks, Inc. Allow incoming SIP If set to “Yes”, the device will ignore any SIP message that does not come from the IP address (Source IP in the IP header) that it is registered to. Default messages from SIP setting is “No”.
  • Page 27 HandyTone-486 User Manual Grandstream Networks, Inc. NAT Traversal This setting decides whether the NAT traversal mechanism is activated. It should be set to “Yes” if the device is behind a NAT router. If no outbound proxy is configured, a STUN server needs to be set to activate STUN detection mechanism.
  • Page 28 HandyTone-486 User Manual Grandstream Networks, Inc. Polarity Reversal Select Polarity Reversal to adapt some call charge/billing system. Default is “No”. NTP server This is the URI or IP address of the NTP (Network Time Protocol) server, which the HandyTone ATA will use to synchronize the date/time.
  • Page 29 HandyTone-486 User Manual Grandstream Networks, Inc. WAN Side HTTP Default is “No”. The access to configuration page via WAN port is disabled. This setting has no effect if the device is in Bridge mode. Access PSTN Access Code Default is “*00”. User can switch the phone to PSTN line connected to the Line port of ATA and make outgoing calls.
  • Page 30: Saving The Configuration Changes

    Saving the Configuration Changes Once a change is made, users should click on the “Update” button in the Configuration page. The HandyTone-486 will then display the following screen to confirm that the changes have been saved. Grandstream Device Configuration STATUS BASIC SETTINGS ADVANCED SETTINGS Your configuration changes have been saved.
  • Page 31: Configuraentraltion Through Aentral Centraentrall Server

    The device is rebooting now... You may relogin by clicking on the link below in 30 seconds. Click to relogin All Rights Reserved Grandstream Networks, Inc. 2005 Configuration through a Central Server Grandstream HandyTone ATAs can be automatically configured from a central provisioning system.
  • Page 32: Software Upgrade

    HandyTone-486 User Manual Grandstream Networks, Inc. Software Upgrade Software upgrade can be done via either TFTP or HTTP. The corresponding configuration settings are in the ADVANCED SETTINGS configuration page. Firmware Upgrade through TFTP/HTTP To upgrade via TFTP or HTTP, the “Firmware Upgrade and Provisioning upgrade via” field needs to be set to TFTP or HTTP, respectively.
  • Page 33: Configuration File Download

    “cfg000b820102ab”. The configuration file name should be in lower cases. Firmware and Configuration File Prefix and Postfix Starting from firmware version 1.0.7.11 for HandyTone-486 Rev 2.0, adding prefix and postfix for both firmware and configuration file is supported. Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix and Postfix.
  • Page 34: Restore Factory Default Setting

    The device will reboot automatically and restore to factory default setting. NOTE: • Please be aware by default the HandyTone-486 WAN side HTTP access is disabled. After a factory reset, the device’s web configuration page can be accessed only from its LAN port,...
  • Page 35: Glossary Of Terms

    HandyTone-486 User Manual Grandstream Networks, Inc. Glossary of Terms ADSL Asymmetric Digital Subscriber Line: Modems attached to twisted pair copper wiring that transmit from 1.5 Mbps to 9 Mbps downstream (to the subscriber) and from 16 kbps to 800 kbps upstream, depending on line distance.
  • Page 36 HandyTone-486 User Manual Grandstream Networks, Inc. divided into 24 time slots of 10ms, and twelve full-duplex accesses per carrier, for a total of 120 possible combinations. A DECT base station (an RFP, Radio Fixed Part) can transmit all 12 possible accesses (time slots) simultaneously by using different frequencies or using only one frequency.
  • Page 37 HandyTone-486 User Manual Grandstream Networks, Inc. Foreign eXchange Station An FXS device has hardware to generate the ring signal to the FXO extension (usually an analog phone). An FXS device will allow any FXO device to operate as if it were connected to the phone company.
  • Page 38 HandyTone-486 User Manual Grandstream Networks, Inc. format and compression/translation of the signal into Internet protocol (IP) packets for transmission over the Internet or other packet-switched networks; the process is reversed at the receiving end. The terms IP Telephony and Internet Telephony are often used to mean the same;...
  • Page 39 HandyTone-486 User Manual Grandstream Networks, Inc. i.e. the phone service we use for every ordinary phone call, or called POT (Plain Old Telephone), or circuit switched network. RTCP Real-time Transport Control Protocol, defined in 3550, a sister protocol of the...
  • Page 40 HandyTone-486 User Manual Grandstream Networks, Inc. another. UDP does not provide the reliability and ordering guarantees that does; datagrams may arrive out of order or go missing without notice. However, as a result, UDP is faster and more efficient for many lightweight or time-sensitive purposes.

Table of Contents