PACH & COMPANY AeGIS 7000 Series Installation And Programming Manual page 13

Aegis 7000 series
Hide thumbs Also See for AeGIS 7000 Series:
Table of Contents

Advertisement

A 12 VAC 40VA transformer is supplied by Pach and Company. However, 12 VDC 40VA power supply or 12VDC
5
power
supply with battery backup can be used to power the AeGIS 7000 Series, use the same connection as shown on figure 2.1.
• Two conductors, 18-gauge shielded stranded wires must be used. Ground one end of the shielded to earth
ground. See installation instruction if ASP1 Surge Protector is used.
• Do not share power transformer or power supply between the AeGIS and other electronic equipment.
• Turn the power "ON" (left position). The Power Light Emitting Diode (LED2) should be "ON". You should see
"Welcome to Pach's Telephone Access Systems" on the Liquid Crystal Display (LCD). If the display is blank, turn
the system off and see Chapter 4.0 Operations and Chapter 6.0 Trouble Shooting Guides.
BATTERY BACKUP
6
The AeGIS 7000 Series have built-in charging circuit for battery backup. The battery will keep the system in full operation
during power failure. Recommended battery is 12 VDC, 4.5 Ahr rechargeable (customer supply). The life of the battery is
approximately 8 hours in idle mode.
• Use two conductors 18-gauge shielded stranded wires.
WARNING: The connection is polarity sensitive. Connect the battery (+) terminal to the connector labeled (BAT) on the
AeGIS and the battery (-) terminal to the connector labeled LCOM on the AeGIS. See figure 2.1 for wiring
diagram.
7
NIGHT LIGHT
14V 0.080A 15,000 Average life hours light bulbs. Use the same rating of replacement light bulb.
Pach and Company
AeGIS 7000 Series
Chapter 2
INSTALLATION
Page 6

Advertisement

Table of Contents
loading

Table of Contents