Firstech CM7200 Master Manual page 26

Starter system
Table of Contents

Advertisement

CM7200 Master Guide
Timer Start, or, Minimum
2-06
Interval Between Cold Starts
Remote Start Runtime
2-07
Temperature of Cold Starting
2-08
Temperature of Hot Starting
2-09
Engine Sensing
2-10
Advanced Tachless
2-11
Crank Time
2-12
Timer Mode
2-13
Emergency Brake or Parking
2-14
Light Reminder Input
Feature
Parking lights While Remote
3-01
Started
Confirmation Chirps
3-02
Dome Light Delay
3-03
Starter-Kill Relay
3-04
Factory Style Alarm
3-06
Horn Output
3-08
Siren Output
3-09
Valet
3-10
Auxiliary Settings Mode
3-11
VAC (Ventilation, Air
3-12
Conditioning)
Defroster Temperature
3-13
Control
Defroster Output Timing
3-14
Soft Disarm
3-15
RPS
3-16
Copyright 2014 Firstech, LLC.
Copyright 2014 Firstech, LLC.
Copyright 2014 Firstech, LLC.
Option Group 2
2 Hour Repeat with
3 Hour (4 minute
Cold Starting of 2-08
runtime, double for
(Runtime set by 2-07)
Diesel)
2 Way LCD Remotes Only
15 Min
-10° C / 14° F
25° C / 77° F
Tach
Off
Standard
Off
(-) Emergency Brake
Input
Option Group 3
Default Setting - I
Optional Setting - II
Constant Output
Medium (30 ms)
Off
Anti-Grind + Starter
Kill
Off
On Double Lock Only
On Lock and Unlock
On Lock, Unlock, and
On Double Lock Only
Start
Brake + Key 5 times
Key 5 times or Remote
or Remote (Lock +
Trunk) w/Ign. On
Disabled
Above 100 Degrees F
Above 90 Degrees F
Standard
0.5 sec pulse
Off
FT-RPS Touch
Reservation (Runtime
set by 2-7)
25 Min
-20° C / -4° F
-5° C / 23° F
30° C / 86° F
35° C / 95° F
No Connection -
Alternator
Tachless Sensing
(Automatic Trans Only)
On
+0.2 Seconds to
+0.6 Seconds to
Crank Time
On
(-) Parking Light
(-) Trigger Start Input
Reminder Input
Optional Setting - III Optional Setting - IV
Flashing Output
Short (15 ms)
Normal (60 ms)
5 sec
Anti-Grind + Passive
Anti-Grind
On
On Lock, Unlock, and
On Lock and Unlock
(+)Keysense Input
(Lock + Trunk)
Enabled
Above 80 Degrees F
Only below 32
Only below 42
degrees F
3 min latch
On
FT-RPS 2
Starter System
techfeed.compustar.com
24 Hour Repeat with
Cold Starting of 2-8
2 Way LCD
(Runtime set by 2-7)
Remotes Only
Way LCD Only
45 Min
-15° C / 5° F
40° C / 104° F
No Connection – 3
Second Crank
(Automatic Trans Only)
(-)0.2 Second Crank
Crank Time
Off with Lock and
Off
Unlock Only
45 sec
Starter Kill
On Double Lock and
Start
On Double Lock and
Above 90 Degrees
Latched for Runtime
degrees F
Constant Output Until
7 min latch
Remote Start Shuts
2
3 Min
Time
Auto
Start
Start
Down
Page 26
Page 2
Page 2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CM7200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF