Extending An Empty Unit; Replacing Hard Disks - Bosch DIVAR IP 2000 DIP-2040EZ-00N Installation Manual

Table of Contents

Advertisement

DIVAR IP 2000
See also:
8.4.2

Extending an empty unit

You can extend an empty unit with 2 or 4 additional hard disks.
To add hard disks to an empty unit:
1.
2.
3.
4.
See also:
8.4.3

Replacing hard disks

If a hard disk fails, the individual disk status LED to the right of
the disk carrier will turn red.
To replace hard disks:
1.
2.
3.
4.
5.
Bosch Sicherheitssysteme GmbH
Chassis setup, page 16
Insert the new hard disks into the chassis bay, making sure
that the drive carrier handle is completely closed.
Turn on the unit by pressing the power button.
The unit identifies the hard disks as new and starts the
recovery menu automatically.
After finishing the recovery process the DIVAR IP software
is installed. The individual disk status LED to the right of
the disk carrier will turn blue.
Perform a basic configuration using the configuration
wizard.
Chassis setup, page 16
Obtainging a basic configuration, page 20
Remove the defective hard disk. Use the handle to pull the
disk carrier out of the chassis.
Note: You can remove the hard disk during operation.
Turn off the unit by pressing the power button.
Insert the new hard disks into the chassis bay, making sure
that the drive carrier handle is completely closed.
Turn on the unit by pressing the power button.
Open DIVAR IP Dashboard with any browser. To do this, in
the address bar of the web browser, enter http://
mydivar/dlacockpit or http://<IP address of DIVAR
Maintaining the system | en
2014.07 | V1 | DOC
27

Advertisement

Table of Contents
loading

Table of Contents