turn the pOWer OFF At the circuit breAker

inStAllAtiOn

For ease of installation, manufacturer recommends use of a deep wall box.
The device is equipped with flying leads to simplify installation, however, if
desired, they may be removed by loosening the screw terminals.
1. Disconnect power to circuit by turning circuit breaker OFF before
installation.
2. Remove the existing wall plate and switch, if one is present.
3. Strip existing wires 1/2". If two wires will be connected to the same terminal
on a Miro device, both wires must be the same gauge (12AWG or 14AWG).
4. Wire the LINE (black), LOAD, NEUT (white) and GND (green or bare) supply
and load wires to the correspondingly marked screw terminals, according
to the wiring diagram below.
5. Attach the wall plate.
6. Switch the circuit breaker back ON.
inStAll in cOMpliAnce With
All ApplicAble
cOdeS & StAndArdS.
Failure to follow these
instructions may cause
personal injury or equipment
damage.
cAutiOn
beFOre inStAllinG the device.
LOAD
WIRE
NEUT
LOAD
GND
LINE
SUPPLY
WIRE