Data Lock

Use this function in the playback screen to protect data from overwriting. Click a time in the search bar
and then click [Data Lock]. If you set the check mark and confirm with [OK], this 10-minute section is
locked and marked light yellow in the search bar.

Network connection

To connect the digital surveillance system to a network or the Internet, you need a physical connection
via the LAN adapter or a modem.

Client Software

The Client software is used for remote monitoring of the server system via TCP/IP or modem. It
provides the same scope of functions for analysing recorded data as the server software. The client
software is on the CD supplied and must first be installed. Select the [DigiProtect Client] directory and
run "setup.exe". Follow the instructions on the screen and complete the installation correctly.
Start the client software by double-clicking the desktop icon. You are asked to disable the "True Color
Rendering" function of the graphic card (no check mark set). Confirm with [OK].
The client software user interface and the connection dialog now open. You can choose between
modem, TCP/IP or IP server connection. First enter a name for the connection.
For a LAN (Local Area Network) connection, select [TCP/IP] and specify the IP address of the
destination server. For a server logon, you have to enter [ID] and [Password] as registered in the
DigiProtect server under [Setup / Network / User]. Click [Port] to change the communication port
(default: 2000). The port must be identical for the server and the client. You can edit a connection on
the list with [Insert], [Delete] and [replace].
Now click [Connect] to start communication with the server.