3.0
Installation
•
Heater Packaging
Heater Packaging
Heaters are made up of three pieces shipped in two boxes; the burner control box in the first box and the
emitter assembly and reflectors in the second box (see Figure 3.2).
Figure 3.2
•
Heater Packaging
Burner Control Box
Improper suspension of the tube heater may result in collapse and being crushed. Always
suspend from a permanent part of the building structure that can evenly support the total
force and weight of the heater.
Failure to maintain minimum clearance to combustibles may result in fire and/or explosion,
property damage, serious injury or death. Always maintain minimum clearances and post
clearance safety limit signs or the clearance safety tag where needed.
Chart 3.3
•
Heater Mounting Requirements and Weights
Model
Overall Unit Length Suspension Points
AVS-40 [N,P]
AVS-60 [N,P]
AVS-80 [N,P]
Shipping Dimensions:
B = Burner Control Box (15#) & (31.5"L x 17.5"W x 15.5"H)
T = Emitter Assembly and Reflector Box (88#) & (91"L x 31"W x 14"H)
NOTE: See Kit Contents on page 44.
•
2 Pieces
WARNING
!
106"
3 or 4
106"
3 or 4
106"
3 or 4
Emitter Assembly and Reflector Box
Shipping Weight
103 lbs.
103 lbs.
103 lbs.
12
AVS
Series
Chain Set Qty.
3
3
3