Brant Radiant Heaters AVS-40N Instructions Manual page 9

Avs series, gas-fired infrared quad tube heater
Table of Contents

Advertisement

AVS
Series
Chart 2.1
Clearance to Combustibles in Centimeters (see Figure 2.1)
Model Number
AVS-40 [N, P]
AVS-60 [N, P]
AVS-80 [N, P]
Figure 2.1
Clearance to Combustibles
SIDE VIEW
Top
Back
Below
END VIEW
Top
Side
Below
Mount Heater Level
- Side to Side -
WARNING
!
Failure to comply with the stated clearances to combustibles may result in
personal injury, property damage and/or death.
Failure to mount the appliance level may result in personal injury, property
damage and/or death.
Top
Sides
25.4
91.44
25.4
91.44
25.4
91.44
Mount Heater Level
- Front to Back -
BACK VIEW Showing Pitched Roof Installation
Side
2.0
Safety
Below
101.6
101.6
101.6
10"
36"
Mount Heater Level
- Side to Side -
9
Clearance to Combustibles
Back
End
15.24
30.48
15.24
30.48
15.24
30.48
End
36"

Advertisement