Tamb
Start cooling
Tpreset +1 ˚C
Original operating status
Tpreset –1 ˚C
Stop cooling
≥ 6 min.
≥ 3 min.
≥ 6 min.
Compressor
Outdoor fan
Set fan spee d
Indoor fan
Run
Stop
During freeze protection
min
Compressor
Outdoor fan
Indoor fan
Preset speed
Run
Stop