Check After Installation And Test Operation; Air Purging And Leakage Test; Outdoor Condensate Drainage; Items To Be Checked - Vivax ACP-12CH35GEF Service Manual

Hide thumbs Also See for ACP-12CH35GEF:
Table of Contents

Advertisement

Items to be checked

Has it been fixed firmly?
Have you done the refrigerant leakage test?
Is heat insulation sufficient?
Is water drainage satisfactory?
Is the voltage in accordance with the rated
voltage marked on the nameplate?
Is the electric wiring and piping
connection installed correctly and securely?
Has the unit been connected to a secure
earth connection?
Is the power cord specified?
Are the inlet and outlet openings blocked?
Is the length of connection pipes
and refrigerant capacity been recorded?
-76cmHg
Low-pressure
valve (Lo) Open
Liquid valve
Gas valve
Possible malfunction
The unit may drop, shake or emit noise.
It may cause insufficient cooling(heating)
capacity
It may cause condensation and dripping.
It may cause condensation and dripping.
It may cause electric malfunction
or damage the product.
It may cause electric malfunction
or damage the part.
It may cause electrical leakage.
It may cause electric malfunction
or damage the part.
It may cause insufficient cooling(heating)
capacity.
The refrigerant capacity is not accurate.
Manometer
High-pressure
valve (Hi) closed
Charging hose
Vacuum
pump
Fig.6
Drain-water hole
Bottom frame
Drain connecter
Hose (available commercially,
inner dia. 16mm)