Starting A Local Management Session - Allied Telesis AT-9408LC/SP Installation Manual

At-9400 series layer 2+ gigabit ethernet switches
Hide thumbs Also See for AT-9408LC/SP:
Table of Contents

Advertisement

Chapter 2: Installation

Starting a Local Management Session

56
The procedure in this section explains how to start a local (out-of-band)
management session using the RJ-45 terminal port on the switch. You can
use a local management session to configure the switch's operating
parameters and view performance and error statistics.
Note
If your network already has an enhanced stack of Allied Telesyn
Layer 2 or Layer 2+ switches, you may be able to remotely manage
the new switch by connecting, locally or remotely, to the master
switch of the stack and changing to the new switch through the
management software. For overview information on enhanced
stacking, refer to the AT-S63 Management Software Menus
Interface User's Guide.
To start a local management session, perform the following procedure:
1. Connect the RJ-45 end of the management cable included with the
AT-9400 Series switch to the Terminal Port on the front panel of the
switch, as shown in Figure 30.
Figure 30. Connecting the Management Cable to the RJ-45 Terminal Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
a personal computer with a terminal emulation program.
3. Configure the terminal or terminal emulation program as follows:
Baud rate: Default is 9600 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
464
on the Switch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents