Technical data

Engine
Max. output, kW
Rated current 3-phase at 400V, A
Rated current 1-phase, A
3-phase voltage in, V
1-phase voltage in, V
Power supply
3 phase
Single-phase
Effect generator - min., kWA
400V, 16A
Weight, kg
Power pack
Water cooling
Water pressure - max, bar
Water coolant flow min., l/min
Max cooling water temperature at 3,5 l/min, ºC
Control system
Control type
Signal transmission
Dimensions
Typical generator operation cases
PP220, power output
Full power
3 phase
Decreased power
Single-phase
Decreased power

Recommended cable dimensions

NOTICE! Good motor performance depends on proper voltage. Extension cables that are too long and/or which have
a gage that is too small, reduce power to the motor under load, resulting in reduced output or malfunctions.
TECHNICAL DATA
PP220
6,5
12
16
200-480
220-240
L1+L2+L3+N+PE/L1+L2+L3+PE
L+N+PE
12
10,8
7
3,5
25
Remote control
Wireless/cable
Generator output voltage (V)
3x400, 3x416, 3x440, 3x480
3x208, 3x220, 3x240
220-240
Minimum recommended
generator output (kVA)
10
5