Error Messages - Husqvarna PP220 Operator's Manual

Wall saw
Hide thumbs Also See for PP220:
Table of Contents

Advertisement

Available languages

Available languages

Error messages

In case of any faults, a fault message (1) and a fault code (2) appears on the display. Please observe, the illustration
shows an example.
Low voltage detected on voltage bus.
Check the power supply connection.
1
2011-09-09 12:45
2
CODE: F0109
Measures for acknowledging fault messages:
Press 'OK' on the display or activate the trigger on the connected tool. No further action is required if the fault
message is deleted.
If the system freezes and an acknowledgment can not be made: Pull out the connector from the earthed socket outlet,
reconnect the power source. See instructions in the section "Assembling and adjustments".
If the fault persists, follow the instructions given in the troubleshooting guide or get in touch with an authorized dealer.
The power unit software can be updated. Contact your service agent for further information.
Troubleshooting schedule
Fault Code
Error messages
F0101
Over current detected
F0103
Fault detected in hardware Hardware fault
Error detected on the
F0104
voltage bus
High voltage detected on
F0105
voltage bus. Check the
power supply connection.
Temperature in the IGBT
F0106
module too high
Emergency stop switch
F0107
pressed
High motor temperature
FXX08*
detected
Low voltage detected on
F0109
voltage bus. Check the
power supply connection.
Cooling fan fault detected.
F0110
Check the cooling fan
The clock has stopped,
F0111
please correct it if
neccessary.
F0112
Low input voltage detected Input voltage too low
High input voltage
F0113
detected
Tool temperature sensor
FXX14*
error detected
F0215
Travel motor has stopped
F0216
Depth motor has stopped
F0117
Fault detected in hardware Hardware fault
F0118
Fault detected in hardware Hardware fault
Temperature in the PP too
F0119
high
* XX different numbers depending on the tool that is connected to the power unit.
20 – English
MAINTENANCE
OK
OK
Cause
Active tool current too high
Tool voltage error
Brakes applied too hard
Power pack overheated
The emergency stop is pressed in.
Tool motor temperature is too high
Internal power pack failure
Fan does not work
Clock stopped
Input voltage too high
Interruption or short circuit in the
temperature sensor.
Hit track end stop
Dirt on track
Blade is stuck
Blade is stuck
Power pack overheated
Steps
Contact your service workshop if the problem
remains.
Contact your service workshop if the problem
remains.
Check the power supply
Contact your service workshop if the problem
remains.
Increase the flow of water coolant. Ensure clean
water is used so as not to clog up the water
channels. See Technical data for specifications for
water flow, temperature and pressure.
Reset the emergency stop
Increase the flow of water coolant. Ensure clean
water is used so as not to clog up the water
channels. See Technical data for specifications for
water flow, temperature and pressure.
Check input power or contact service
Check the fan. Replace as necessary.
Contact your service agent for a battery change.
Check minimum input power in manual
Check maximum input power in manual
Contact your service agent.
Clean the wall saw rail and check that the wall saw
and rail are securely fixed.
Contact your service workshop if the problem
remains.
Check that the wall saw and rail are securely fixed.
Contact your service workshop if the problem
remains.
Contact your service workshop if the problem
remains.
Contact your service workshop if the problem
remains.
Increase the flow of water coolant. Ensure clean
water is used so as not to clog up the water
channels. See Technical data for specifications for
water flow, temperature and pressure.