Front Panel Leds And Buttons - HP ProLiant ML310e User Manual

V2 server
Hide thumbs Also See for ProLiant ML310e:
Table of Contents

Advertisement

Front panel LEDs and buttons

Item
Description
UID button/LED
1
Health LED
2
NIC status LED
3
Power On/Standby button
4
and system power LED
*To identify components in a degraded or critical state, see the Systems Insight Display LEDs, check iLO/BIOS logs, and
reference the server troubleshooting guide.
**Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has
occurred, or the power button cable is disconnected.
Status
Solid blue = Activated
Flashing blue (1 Hz/cycle per sec) = Remote management or
firmware upgrade in progress
Off = Deactivated
Solid green = Normal
Flashing amber = System degraded
Flashing red (1 Hz/cycle per sec) = System critical
Fast-flashing red (4 Hz/cycles per sec) = Power fault*
Solid green = Link to network
Flashing green (1 Hz/cycle per sec) = Network active
Off = No network activity
Solid green = System on
Flashing green (1 Hz/cycle per sec) = Performing power on sequence
Solid amber = System in standby
Off = No power present**
Component identification 7