Specifications
Environmental specifications
Specification
Temperature range*
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
* All temperature ratings shown are for sea level. An altitude derating of 1° C per 304.8 m (1.8° F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Height
Depth
Width
Weight, minimum with SFF drive cage
Weight, maximum with SFF drive cage
Weight, minimum with LFF drive cage
Weight, maximum with LFF drive cage
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP 350 W 4U Integrated Power Supply
•
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
Value
10° C to 35° C (50° F to 95° F)
-30° C to 60° C (-22° F to 140° F)
10% to 90%
5% to 95%
Tower model
36.82 cm (14.50 in) 17.50 cm (6.89 in)
47.52 cm (18.71 in) 47.52 cm (18.71
17.50 cm (6.89 in)
11.00 kg (24.22 lb)
17.00 kg (37.44 lb)
11.90 kg (26.21 lb)
19.00 kg (41.85 lb)
Rack model
in)
36.82 cm (14.50
in)
11.00 kg (24.22
lb)
17.00 kg (37.44
lb)
11.90 kg (26.21
lb)
19.00 kg (41.85
lb)
Specifications 83