Specifications Of Electrical Parts; Outdoor Unit - Toshiba RAV-SM2244AT8-A Service Manual

Split type air conditioner
Table of Contents

Advertisement

5. SPECIFICATIONS OF ELECTRICAL PARTS

5-1. Outdoor Unit

RAV-SM2244AT8-A, RAV-SM2804AT8-A
No.
1
Compressor
2
Outdoor fan motor
3
4-way valve coil
4
2-way valve coil
5
PMV coil
6
High pressure switch
7
Reactor
8
Reactor
9
Reactor
10
P .C. board (Compressor drive)
11
P .C. board (Fan motor drive)
12
P .C. board (Control)
13
P .C. board (Noise filter)
14
P .C. board (Fan extention)
15
Outdoor temp. sensor (TO sensor)
16
Discharge temp. sensor (TD sensor)
17
Suction temp. sensor (TS sensor)
18
Heat exchanger sensor (TE sensor)
19
Heat exchanger mid. temp. sensor (TL sensor)
20
Fuse
21
Fuse (Mounted on P.C. board, MCC-1596)
22
Fuse (Mounted on P.C. board, MCC-1596)
23
Fuse (Mounted on P.C. board, MCC-1597)
24
Fuse (Mounted on P.C. board, MCC-1597)
25
Fuse (Mounted on P.C. board, MCC-1599)
26
Fuse (Mounted on P.C. board, MCC-1600)
27
Relay
28
Posistor
29
Compressor thermo.
Parts name
Type
DA550A3F-11M
ICF-280-A100-1
STF-01AJ502E1
VPV-MOAJ524C0
UKV-25D22
ACB-4UB83W
CH-44
CH-68
CH-56
MCC-1596
MCC-1597
MCC-1599
MCC-1600
MCC-1436
TLC 25A
GAC1 31.5A
SCT 31.5A
GDM 250V 15A
SCT 31.5A
FJL 250V 31.5A
ET 6.3A
EL200/240A2-F(M)
ZPR0YCE 101A 500
US-622
– 16 –
Specifications
DC 280 V, 100 W
AC 220 – 240 V, 50 Hz
AC 220 – 240 V, 50 Hz
DC 12 V
OFF : 4.15 MPa
1.4 mH, 25 A
18 mH, 5 A
5.8 mH, 18.5 A
10 kΩ at 25°C
50 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
25 A, 250 V
31.5 A, 500 V
T3.15 A, AC 250 V
15 A, 250 V
T3.15 A, AC 250 V
T3.15 A, AC 250 V
T6.3 A, AC 250 V
Contact : AC 480 V, 20A
100 Ω, 500 V
OFF : 125 ± 4 °C, ON : 60 ± 5 °C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-sm2804at8-a