Toshiba RAV-SM2244AT8-A Service Manual page 91

Split type air conditioner
Table of Contents

Advertisement

Digital Inverter
No.
Cause
1
Normal
2
Discharge (TD) sensor error
3
Heat exchanger (TE) sensor error
4
Heat exchanger (TL) sensor error
5
Outside air temperature (TO) sensor error
6
Suction (TS) sensor error
7
Heat sink (TH) sensor error
Outdoor temperature sensor (TE/TS)
8
connection error
9
Outdoor EEPROM error
10
Compressor breakdown
11
Compressor lock
12
Current detection circuit error
13
Thermostat for compressor activated
Model data not set (on the service P.C.
14
board)
15
MCU-MCU communication error
16
Discharge temperature error
Abnormal power (open phase detected or
17
abnormal voltage)
18
Heat sink overheat
19
Gas leak detected
20
4-way valve reverse error
21
High pressure release operation
22
Outdoor fan motor error
23
Compressor driver short-circuit protection
Position detection circuit error in one-line
24
display
EN-25
Display mode 1
Display mode 2
D800 D801 D802 D803 D804 D800 D801 D802 D803 D804
13
No.
Cause
25
Ps sensor error
26
Ps drop down error
27
High pressure SW error
* The LEDs and DIP switches are
located on the lower left of the P.C.
board of the outdoor unit.
Installation Manual
Display mode 1
Display mode 2
D800 D801 D802 D803 D804 D800 D801 D802 D803 D804
(
: OFF
: ON
ON
ON
1
2
3
4
1
2
3
4
Enlarged view of
SW804
SW805
ON
ON
1
2
3
4
1
2
3
4
SW802
SW803
SW800 SW801 SW806
LED
D805
D804
D803
D802
D801
D800
: Flashing)
LEDs
D805
D804
D803
D802
D801
D800
EN-26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-sm2804at8-a